Toshiba ACE-tronics G9 ASD Installation And Operation Manual page 224

Adjustable speed drive
Hide thumbs Also See for ACE-tronics G9 ASD:
Table of Contents

Advertisement

F916
Input Function Target 3
Program  My Function  My Function Unit 3
This parameter plays a role in the setup of the My Function feature by
selecting the functionality of the programmable Input Function Target 3
terminal.
This setting assigns the function of the programmable Input Function Target 3
terminal to any one of the user-selectable functions listed in
Table 10 on pg.
242, or
Table 12 on pg.
See
F977
for additional information on this parameter.
Output Function Assigned
Program  My Function  My Function Unit 3
This parameter plays a role in the setup of the My Function feature by
selecting the functionality of the Output Function Assigned terminal.
This setting assigns the function of the programmable Output Function
Assigned data location to one of the functions listed in the Input Setting field
of
Table 10 on pg.
242.
Settings:
0 – 3099
See
F977
for additional information on this parameter.
My Function Percent Data 1
Program  My Function  My Function Data
This parameter is used to set the trigger threshold level of the analog signal of
the My Function Percent Data 1.
The analog signal is selected using the Input Setting number from
pg.
242.
Once the assigned output value reaches the threshold setting of this parameter
the output value is transferred to My Function Out 1.
See
F977
for additional information on this parameter.
My Function Percent Data 2
Program  My Function  My Function Data
This parameter is used to set the trigger threshold level of the analog signal of
the My Function Percent Data 2.
The analog signal is selected using the Input Setting number from
pg.
242.
My Function Percent Data 3
Program  My Function  My Function Data
This parameter is used to set the trigger threshold level of the analog signal of
the My Function Percent Data 3.
The analog signal is selected using the Input Setting number from
pg.
242.
214
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
Table 9 on pg.
245.
Table 10 on
Table 10 on
Table 10 on
ACE-tronics G9 ASD Installation and Operation Manual
Direct Access Number — F916
Parameter Type — Selection List
Factory Default — 0 (Disabled)
Changeable During Run — Yes
241,
Direct Access Number — F917
Parameter Type — Selection List
Factory Default — 0 (Disabled)
Changeable During Run — Yes
Direct Access Number — F918
Parameter Type — Numerical
Factory Default — 0.00
Changeable During Run — Yes
Minimum — 0.00
Maximum — 200.00
Units — %
Direct Access Number — F919
Parameter Type — Numerical
Factory Default — 0.00
Changeable During Run — Yes
Minimum — 0.00
Maximum — 200.00
Units — %
Direct Access Number — F920
Parameter Type — Numerical
Factory Default — 0.00
Changeable During Run — Yes
Minimum — 0.00
Maximum — 200.00
Units — %
F920