Toshiba ACE-tronics G9 ASD Installation And Operation Manual page 140

Adjustable speed drive
Hide thumbs Also See for ACE-tronics G9 ASD:
Table of Contents

Advertisement

F261
Jog Stop Pattern
Program  Frequency  Jog
This parameter sets the stopping method used while operating in the Jog mode.
Note:
This parameter setting is used for the Jog operation only. The
Emergency Off stopping method setting of parameter
priority over this setting and changes made here do not affect the
function or setting of parameter F603.
Settings:
Deceleration Stop
Coast Stop
DC Injection Braking Stop
Panel Operation Jog Mode
Program  Frequency  Jog
This parameter enables the Jog command to be received from the EOI. When
disabled the Jog command received from the EOI is ignored.
Jog commands may also be received from the ACE G9-120V-PCB. Priority as
to which is allowed to override the other is selected at F106.
The priority selection at
F106
disables the other. The
F106
Settings:
Disabled
Enabled
130
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
enables the selected source for Jog control and
setting overrides this parameter setting.
Direct Access Number — F261
Parameter Type — Selection List
Factory Default — Deceleration Stop
Changeable During Run — Yes
F603
has
Direct Access Number — F262
Parameter Type — Selection List
Factory Default — Disabled
Changeable During Run — Yes
ACE-tronics G9 ASD Installation and Operation Manual
F262

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents