DBR OL (Overload) Trip — Displays the DBR Overload Trip value as a percentage of the Dynamic
Braking Resistor capacity.
DBR Load — Displays the DBR Load as a percentage of the Dynamic Braking Resistor capacity.
Feedback (Inst) — Provides a status of the Real Time Feedback in Hz.
Feedback (1 Second) — Provides a status of the 1-Second Averaging feedback in Hz.
Torque — Displays the Output Torque as a percentage of the rated capacity of the ASD.
Torque Reference — Displays the Torque Reference as a percentage of the maximum torque
available.
Torque Current — Displays the torque-producing current value.
Excitation Current — Displays the current value required to produce the excitation field.
PID Feedback — Provides a status of the PID Real Time Feedback in Hz.
Input Power — Displays the Input Power in Kilowatts (kW).
Output Power — Displays the Output Power in Kilowatts (kW).
Pattern Group Number — Displays the active Pattern Run Group Number.
Pattern Cycle Number — Displays the cycle number of the active Pattern Run Group.
Pattern Preset — Displays the active Preset Speed being run of the active Pattern Run Group.
Pattern Time — Displays the remaining time for the active Pattern Run Group.
RR — Displays the RR input value as a percentage of the full range of the RR value (potentiometer
input).
V/I — Displays the V/I input setting as a percentage of the full range of the V/I value.
Note:
The isolated V/I input terminal may receive Current or Voltage to control the output
speed or the output torque. The input signal type must be selected at SW2 on the
ACE G9-120V-PCB.
The V input setting of SW2 is used for the 0 – 10 VDC analog input signal and the I
input setting of SW2 is used for the 0 – 20 mA analog input signal. Either may be used
as a frequency or torque command source. See parameter
on the setup of this terminal.
RX — Displays the RX input setting as a percentage of the full range of the RX value (±10 VDC input).
RX2 Option (AI1) — Displays the RX2 input setting as a percentage of the full range of the RX2 value.
Note:
The RX2 function is available on the Expansion IO Card Option 1 option board
(P/N ETB003Z) only.
Trip Code — Displays None if there are no errors, or displays one of the associated Fault Codes listed
in
Table 15 on page 254
ACE-tronics G9 ASD Installation and Operation Manual
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
if there is an active Fault (e.g., E = Emergency Off).
F201
for more information