Ametek DR6500 Handbook page 87

80 ghz radar (fmcw) level transmitter for powders and dusty atmosphere
Table of Contents

Advertisement

DR6500
Menu
Function
No.
C6.5 2nd Meas. Page
C6.5 2nd Meas. Page
C6.5 2nd Meas. Page
C6.5 2nd Meas. Page
C6.5.1
Function
C6.5.2
1st Value
Variable
C6.5.3
0% Range
C6.5.4
100% Range
C6.5.5
Format 1st
Value
C6.5.6
2nd Value
Variable
C6.5.7
Format 2nd
Value
DR6500-PM-English-Issue 1
Function description
This menu item changes the configuration
of data shown on the display screen in
Normal mode. There are two measurement
pages available to show readings in Normal
mode. This setting is for the second page.
Minimum access level to change the
Minimum access level to change the
Minimum access level to change the
Minimum access level to change the
setting: User
setting:
setting:
setting:
This changes the measurement type of the
first value on the measurement page.
Minimum access level to change the
Minimum access level to change the
Minimum access level to change the
Minimum access level to change the
setting: User
setting:
setting:
setting:
This is the 0% value given to the bar graph
indicator in Normal mode. The range is
related to the measurement type set in
C6.5.2 1st Value Variable. This menu item is
only available if you set C6.5.1 Function to
"One Value & Bar" or "Two Values & Bar".
Minimum access level to change the
Minimum access level to change the
Minimum access level to change the
Minimum access level to change the
setting: User
setting:
setting:
setting:
This is the 100% value given to the bar graph
indicator in Normal mode. The range is
related to the measurement type set in
C6.5.2 1st Value Variable. This menu item is
only available if you set C6.5.1 Function to
"One Value & Bar" or "Two Values & Bar".
Minimum access level to change the
Minimum access level to change the
Minimum access level to change the
Minimum access level to change the
setting:
setting: User
setting:
setting:
You can change the number of decimal
places that are shown for the first value on
the measurement page in Normal mode.
For example, if you set this menu item to
"X.XX", the value shown will be corrected to
2 decimal places. If you set this menu item
to "Automatic", the device will adjust the
number of decimal places automatically.
Minimum access level to change the
Minimum access level to change the
Minimum access level to change the
Minimum access level to change the
setting:
setting: User
setting:
setting:
This changes the measurement type of the
second value on the measurement page.
This menu item is only available if you set
C6.5.1 Function to "Two Values", "Two
Values & Bar" or "Three Values".
Minimum access level to change the
Minimum access level to change the
Minimum access level to change the
Minimum access level to change the
setting: User
setting:
setting:
setting:
You can change the number of decimal
places that are shown for the second value
on the measurement page in Normal mode.
For example, if you set this menu item to
"X.XX", the value shown will be corrected to
2 decimal places. If you set this menu item
to "Automatic", the device will adjust the
number of decimal places automatically.
Minimum access level to change the
Minimum access level to change the
Minimum access level to change the
Minimum access level to change the
setting: User
setting:
setting:
setting:
www.drexelbrook.com
OPERATION
Selection list
One Value, One Value &
Bar, Two Values, Two
Values & Bar, Three
Values
Level, Distance, Sensor
Value, Reflection
2
Refer to "Function
description".
Refer to "Function
description".
X, X.X, X.XX, X.XXX,
X.XXXX, X.XXXXX,
X.XXXXXXX, Automatic
Level, Distance, Sensor
Value, Reflection
2
X, X.X, X.XX, X.XXX,
X.XXXX, X.XXXXX,
X.XXXXXXX
6
Default
Three Values
Distance
Refer to
"Function
description".
Refer to
"Function
description".
X.XXX
Level
X.XXX
87