CAUTION!
Use multi-purpose grease that is applicable for the operating temperature range of the O-ring
with the properties that follow:
Operating temperature range of -40...+130
lubrication of the O-ring
Without silicone
The bonding properties must be satisfactory
Lithium-saponified
Water-resistant
Agrees with the O-ring material

7.1.3 How to clean the top surface of the device

WARNING!
Do not let more than 5 mm / 0.2
possible source of ignition in a potentially explosive atmosphere.
DANGER!
Risk of electrostatic discharge from the gray plastic sun cover.
Obey these instructions:
• Keep the thread of the terminal compartment cover clean.
• If dirt collects on the device, clean it. Wipe the plastic sun cover with a damp cloth.

7.2 Service warranty

WARNING!
Only approved personnel can do an inspection of the device and repairs. If you find a problem,
send the device back to your supplier for inspection and/or repairs.
Servicing by the customer is limited by warranty to:
• The removal and installation of the device.
For more data on how to prepare the device before you send it back, refer to
device to the manufacturer

7.3 Spare parts availability

The manufacturer adheres to the basic principle that functionally adequate spare parts for each
device or each important accessory part will be kept available for a period of 3 years after
delivery of the last production run for the device.
This regulation only applies to spare parts which are subject to wear and tear under normal
operating conditions.
DR6500-PM-English-Issue 1
°
C / -40...+266
¨
of dust collect on the top surface of the device. This is a
on page 114.