Ametek DR6500 Handbook page 78

80 ghz radar (fmcw) level transmitter for powders and dusty atmosphere
Table of Contents

Advertisement

OPERATION
6
C – Full Setup menu
Menu
Function
No.
C1 Install. Parameters
C1.1
Tank Type
C1.2
Tank Height
C1.5
Blocking
Distance
C1.6
Time Constant
C1.7
Antenna Type
C1.8
Antenna
Extension
C1.9
Distance piece
78
Function description
The conditions in which the device is used. If
the surface of the product is flat, select
"Flat surface". If there is a slightly uneven
surface, select "Medium slope". If the
surface has a steep slope, select "Steep
slope".
Minimum access level to change the
Minimum access level to change the
Minimum access level to change the
Minimum access level to change the
setting:
setting:
setting: Expert
setting:
Tank height is the distance from the flange
face/thread stop of the process connection
to the tank bottom. If you use the device for
an LPR (open-air) application, this value is
the maximum distance that the device must
measure (the measuring range).
Minimum access level to change the
Minimum access level to change the
Minimum access level to change the
Minimum access level to change the
setting: Operator
setting:
setting:
setting:
The distance from the flange facing or the
thread stop to the top limit of the measuring
range (a zone given by the user where it is
not possible to measure). We recommend a
minimum blocking distance of 300 mm / 12¨
below the bottom of the antenna. If the
distance is less than the blocking distance,
the device continues to show the blocking
distance on the display screen.
Minimum access level to change the
Minimum access level to change the
Minimum access level to change the
Minimum access level to change the
setting: Expert
setting:
setting:
setting:
Using this function, the device processes
several measurement readings to filter out
disturbances. Increasing the time constant
will smoothen the integrated readings,
decreasing will roughen the readings. s =
seconds.
Minimum access level to change the
Minimum access level to change the
Minimum access level to change the
Minimum access level to change the
setting: Expert
setting:
setting:
setting:
The type of antenna attached to the device. If
you change the antenna, this setting will
have an effect on C1.2 Tank Height and C1.5
Blocking Distance.
Minimum access level to change the
Minimum access level to change the
Minimum access level to change the
Minimum access level to change the
setting: Expert
setting:
setting:
setting:
Optional antenna extension. These are
attached between the flange and the
antenna. Each segment is 105 mm / 4.1¨
long.
Minimum access level to change the
Minimum access level to change the
Minimum access level to change the
Minimum access level to change the
setting: Expert
setting:
setting:
setting:
Optional distance piece between the
converter and the process connection. This
is for the high-temperature version of the
device. Each segment is 105 mm / 4.1¨ long.
Minimum access level to change the
Minimum access level to change the
Minimum access level to change the
Minimum access level to change the
setting: Expert
setting:
setting:
setting:
www.drexelbrook.com
Selection list
Flat Surface, Medium
Slope, Steep Slope
min-max:
+03
0.0...100.00
mm /
0.0...2362.2¨ /
0.0...196.85 ft
min-max:
0.0...5000.0 mm /
0.0...196.85¨ /
0.0...16.404 ft
min-max:
0....100.0 sec (seconds)
Lens (40mm), Lens
(70mm)
min-max:
0.0...1050 mm /
0.0...41.339¨ /
0.0...3.4449 ft
min-max:
0.0...2000 mm /
0.0...78.740¨ /
0.0...6.5617 ft
DR6500-PM-English-Issue 1
DR6500
Default
Steep Slope
1
20000 mm
/ 787.402¨
/ 65.617 ft
1
Antenna
extension
length +
300 mm / 12¨
30 s
As specified in
the customer
order
0 mm /0¨
1
0 mm / 0¨
1

Advertisement

Table of Contents
loading

Table of Contents