Technical Data - Ametek DR6500 Handbook

80 ghz radar (fmcw) level transmitter for powders and dusty atmosphere
Table of Contents

Advertisement

TECHNICAL DATA

8
8.2 Technical data
INFORMATION!
The following data is provided for general applications. If you require data that is more
relevant to your specific application, please contact us or your local sales office.
Additional information (certificates, special tools, software,...) and complete product
documentation can be downloaded free of charge from the website.
Measuring system
Measuring principle
Frequency range
Max. radiated power (EIRP)
Application range
Primary measured value
Secondary measured value
Design
Construction
Options
Max. measuring range
Min. tank height
Recommended minimum
blocking distance
Min. distance for reflection
measurement
Beam angle
(antenna)
Display and user interface
Display and user interface
Display and user interface
Display and user interface
Display
Interface languages
Measuring accuracy
Resolution
Repeatability
Accuracy
Digital temperature drift
118
2-wire loop-powered level transmitter; FMCW radar
W-band (78...82 GHz)
< -41.3 dBm according to ETSI EN 307 372 (TLPR) and ETSI EN 302 729 (LPR)
Level measurement of powders and granulates
Distance and reflection
Level, volume and mass
The measurement system consists of a measuring sensor (antenna) and a signal
converter
Integrated LCD display (-20..+70°C / -4...+158°F); if the ambient temperature is not
in these limits, then this condition can stop the display
Distance piece (for process temperature: +150...+200°C / +302...+392°F)
Antenna purging system (supplied with a G 1/4 connection)
Weather protection
Lens, DN40 (1½¨): 30 m / 98 ft
Lens, DN70 (2¾¨): 100 m / 328.1 ft
Refer also to "Measuring accuracy" on page 124
1 m / 40¨
0.3 m / 12¨ (add 112 mm / 4.4¨ if the DN40 Lens antenna has an antenna extension)
1 m / 3.3 ft
Lens, DN40 (1½¨): 8°
Lens, DN70 (2¾¨): 4°
Backlit LCD display
128 × 64 pixels in 64-step greyscale with 4-button keypad
English, French, German, Italian, Spanish, Portuguese, Chinese (simplified),
Japanese, Russian, Czech, Polish and Turkish
1 mm / 0.04¨
±1 mm / ±0.04¨
Standard: ±2 mm / ±0.08¨, when distance ≤ 10 m / 33 ft;
±0.02% of measured distance, when distance > 10 m / 33 ft. For more data, refer to
Measuring accuracy
on page 124.
Max. ±10 mm / ±0.39¨ for the full temperature range
www.drexelbrook.com
DR6500
DR6500-PM-English-Issue 1

Advertisement

Table of Contents
loading

Table of Contents