Ametek DR6500 Handbook page 42

80 ghz radar (fmcw) level transmitter for powders and dusty atmosphere
Table of Contents

Advertisement

ELECTRICAL CONNECTIONS
4
Figure 4-3: Procedure for electrical installation
Equipment needed:
• POZIDRIV® PZ1 screwdriver (not supplied)
Procedure
1 Loosen the cable gland. Put the electrical wires into the cable entry. Loosen the terminal
screws with a POZIDRIV® PZ1 screwdriver. Connect the electrical wires to the connector.
2 Tighten the terminal screws with a POZIDRIV® PZ1 screwdriver.
3 Tighten the cable gland.
42
www.drexelbrook.com
DR6500
DR6500-PM-English-Issue 1

Advertisement