Operating Conditions - Ametek DR6500 Handbook

80 ghz radar (fmcw) level transmitter for powders and dusty atmosphere
Table of Contents

Advertisement

DR6500
Reference conditions acc. to EN 61298-1
Reference conditions acc. to EN 61298-1
Reference conditions acc. to EN 61298-1
Reference conditions acc. to EN 61298-1
Temperature
Pressure
Relative air humidity
Target

Operating conditions

Temperature
Temperature
Temperature
Temperature
Ambient temperature
Relative humidity
Storage temperature
Process connection temperature
(higher temperature on request)
Pressure
Pressure
Pressure
Pressure
Process pressure
Other conditions
Other conditions
Other conditions
Other conditions
Dielectric constant (ε
)
r
Ingress protection
Maximum rate of change
Installation conditions
Process connection size
Process connection position
Dimensions and weights
Materials
Housing
Wetted parts, including antenna
Process connection
Slanted flange (option)
Gaskets
Cable gland
Weather protection (Option)
DR6500-PM-English-Issue 1
+15...+25°C / +59...+77°F
1013 mbara ±50 mbar / 14.69 psia ±0.73 psi
60% ±15%
Metal plate in an anechoic chamber. The device has specified settings.
-40...+80°C / -40...+176°F
Ex: see supplementary operating instructions or approval certificates
0...99%
-40...+85°C / -40...+185°F
-50...+150°C / -58...+302°F
The process connection temperature must agree with the temperature limits of the
gasket material. Refer to "Materials" in this table.)
Ex: see supplementary operating instructions or approval certificates
-1...40 barg / -14.5...580 psig
Subject to the process connection used and the process connection temperature.
Guidelines for maximum operating pressure
For more data, refer to
≥1.4
IEC 60529: IP66 / IP68 (0.1 barg / 1.45 psig)
NEMA 250: NEMA type 4X - 6 (housing) and type 6P (antenna)
60 m/min / 196 ft/min
The nominal diameter (DN) should be equal to or larger than the antenna diameter.
Make sure that there are not any obstructions directly below the process
connection for the device. For more data, refer to
For dimensions and weights data, refer to
Standard: Polyester-coated aluminium
Option: Stainless steel (1.4404 / 316L) – non-Ex devices only. Ex approvals will be
available in the second quarter of 2018.
PEEK – this material agrees with FDA regulations
Stainless steel (1.4404 / 316L)
PTFE (≤ +150°C / +302°F); PEEK (> +150°C / +302°F)
FKM/FPM (-40...+150°C / -40...+302°F); EPDM (-50°C...+150°C / -58...+302°F)
Standard: none
Options: Plastic (Non-Ex: black, Ex i-approved: blue); nickel-plated brass; stainless
steel; M12 (4-pin connector)
Stainless steel (1.4404 / 316L)
www.drexelbrook.com
TECHNICAL DATA
Installation
on page 22.
Dimensions and weights
8
on page 128.
on page 130.
119