Ametek DR6500 Handbook page 81

80 ghz radar (fmcw) level transmitter for powders and dusty atmosphere
Table of Contents

Advertisement

DR6500
Menu
Function
No.
C3 Conversion
C3.1 Edit Table
C3.1 Edit Table
C3.1 Edit Table
C3.1 Edit Table
C3.1.1
Erase Table?
C3.1.3
Select
Conversion
C3.2 Input Table
C3.2 Input Table
C3.2 Input Table
C3.2 Input Table
C3.2.2
Point
C3.2.4
Level
C3.2.5
Conv. Value
DR6500-PM-English-Issue 1
Function description
Before you can make a conversion table, you
must delete the data that is stored in the
device at this time. If you set this menu item
to "No" you will go back to menu C3.1. If you
set it to "Yes", you will go to menu item
C3.1.3 Select Conversion.
Minimum access level to change the
Minimum access level to change the
Minimum access level to change the
Minimum access level to change the
setting: Expert
setting:
setting:
setting:
If you must make a volume conversion table,
set this menu item to "Volume". If you must
make a mass conversion table, set this
menu item to "Mass". If you must make a
linearization table to make sure that the
readings always agree with reference
measurements, set this menu item to
"Linearization".
Minimum access level to change the
Minimum access level to change the
Minimum access level to change the
Minimum access level to change the
setting: Expert
setting:
setting:
setting:
This adds a point on the conversion table.
Each time you enter this menu item, this
number will automatically increment by 1
point. If it is necessary to change the data
for a point, change the point number. When
you push [^ ^ ^ ^ ], you go to menu item C3.2.4
Level.
Minimum access level to do the procedure:
Minimum access level to do the procedure:
Minimum access level to do the procedure:
Minimum access level to do the procedure:
Expert
Enter the level value for the point given in
C3.2.2. Push [^ ^ ^ ^ ] to confirm the level value
and go to C3.2.5 Conv. Value.
Minimum access level to do the procedure:
Minimum access level to do the procedure:
Minimum access level to do the procedure:
Minimum access level to do the procedure:
Expert
Enter the conversion value (volume, mass or
linearization) for the point given in C3.2.2.
Push [^ ^ ^ ^ ] to confirm the conversion value
and go back to menu C3.2.
Minimum access level to do the procedure:
Minimum access level to do the procedure:
Minimum access level to do the procedure:
Minimum access level to do the procedure:
Expert
www.drexelbrook.com
OPERATION
Selection list
Yes, No
Volume, Mass,
Linearization
min-max:
001...050
min-max:
+03
0.0...100.0
mm /
0.0...3937.0¨
min-max:
Volume:
+09
0.0...100.0
m³ /
+12
0.0...26.417
gal
Mass:
+09
0.0...100.0
kg /
+09
0.0...220.46
lb
Linearization:
+12
0.0...100.0
mm /
+12
0.0...3.937
¨
6
Default
No
Volume
001
0.0 mm / 0.0¨
Volume:
0.0 m³ / 0.0 gal
Mass:
0.0 kg / 0.0 lb
Linearization:
0.0 mm / 0.0¨
81