Avaya Definity SI Maintenance Manual page 2556

Table of Contents

Advertisement

Maintenance Object Repair Procedures
Table 10-649. TEST #36 Audit Update Test — Continued
Error
Code
0
Tie Trunk Seizure Test (#73), Tie Trunk Dial Test
(#747). Seizure Test(#73)
The Tie Trunk Seizure Test activates the M lead and checks for a response from
the external end within 10 seconds. This test is applicable only to wink start and
delay dial outgoing trunks. (For the TN2140 [G3iV2-386] circuit pack, the trunk
must also be continuous-seize-ack and discontinuous-seize-ack).
The Tie Trunk Dial Test seizes the trunk and outpulses a pause digit.
For a port administered as TGU or a TGE, the Seizure Test internally seizes the
trunk and outpulses a "pause." The report reports the result of the seizure attempt
uplink.
10-1770
Issue 4 May 2002
Test
Result
PASS
This test passed. Translation information was successfully
updated on the circuit pack.
1. If signaling troubles are reported, verify translation
information for this port.
(Non-TN439 and non-TN497 circuit packs only.) If the trunk is
busied out, the test does not run, but it does return PASS.
To verify that the trunk is in-service:
1. Enter status trunk to verify that the trunk is in-service.
If the trunk is in-service, no further action is necessary. If the
trunk is out-of-service, continue to Step 2.
2. Enter release trunk to put trunk back into in-service.
3. Retry the test command.
NO
The test could not relate the internal ID to the port (no board).
BOARD
1. Check to ensure that the board translations are correct.
Translate the board, if necessary.
2. Issue the busyout board command.
3. Issue the reset board command.
4. Issue the release busy board command.
5. Issue the test board command. This should re-establish
the linkage between the internal ID and the port.
Description/Recommendation
Continued on next page