Table 2-1 Interpreting Error Beep Codes

Beep
Code
Problem
1
A single beep is emitted when the
SROM code has successfully
completed.
1-3
VGA monitor is not plugged in.
1-1-2
ROM data path error detected
while loading AlphaBIOS/SRM
console code.
System automatically attempts to
boot a fail-safe loader diskette
from the floppy drive.
1-1-4
The SROM code is unable to load
the console code: Flash ROM
header area or checksum error
detected.
System automatically attempts to
boot a fail-safe loader diskette
from the floppy drive.
1-1-7
Floppy read error. System could
not locate a valid boot block on
the diskette.
1-2-1
TOY NVRAM failure.
Power-Up Diagnostics and Display
Corrective Action
Not applicable. No error.
Plug in the graphics monitor.
If you do not want the graphics
monitor, disable the VGA jumper
(J27) on the motherboard. See
Appendix A.
Insert the fail-safe loader diskette into
the floppy drive to load new
AlphaBIOS/SRM console code. (See
the section "Fail-Safe Loader.")
If loading new console firmware does
not solve the problem, replace the
motherboard. (See Chapter 7.)
Insert the fail-safe loader diskette into
the floppy drive to load new console
code. (See the section "Fail-Safe
Loader.")
If loading new console firmware does
not solve the problem, replace the
motherboard. (See Chapter 7.)
Make sure floppy diskette is inserted,
or try another diskette.
Replace the TOY NVRAM chip
(E78) on system motherboard. (See
Chapter 7.)
Continued on next page