Reset; Send Alert; Set Alert - Digital Equipment 3300R Service Manual

Digital server
Table of Contents

Advertisement

Server Management Console

reset

The reset command is the equivalent of pushing the Reset button from the operator control
panel. It causes a full re-initialization of the system firmware. When the reset command
is executed, the user's terminal exits console monitor mode and reconnects to the server's
COM1 port.
Example:
RCM> reset
Returning to COM port.

send alert

The send alert command forces an alert condition. This command can be used to test the
setup of the alert dial out function or to send an alert condition when a system application
program is connected to the RMC monitor program.
Example:
RCM> send alert
RCM>

set alert

The set alert command sets the alert string that is transmitted through the modem when an
alert condition is detected. This string should be set to some meaningful value such as the
system remote access phone number. An application on the remote system could monitor
incoming alert strings and take appropriate action. The maximum string length is 47
characters. When the alert is sent, the dial string and alert string are concatenated and sent
to the modem.
Example:
RCM> set alert
alert>
RCM>
"," is used to cause a 2-second delay, which may be helpful when sending data to numeric
paging services.
"#;" must be used to terminate the alert string.
4–14 DIGITAL Server 3300/3300R
,,,,,,,5085551212#;