Show_Status - Digital Equipment 3300R Service Manual

Digital server
Table of Contents

Advertisement

show_status

Use the show_status command to display the progress of diagnostics. The show_status
command reports one line of information per executing diagnostic. The information
includes ID, diagnostic program, device under test, error counts, passes completed, bytes
written, and bytes read. Many of the diagnostics run in the background and provide
information only if an error occurs.
The following command string, where n is the number of seconds between
displays, is useful for periodically displaying diagnostic status information for diagnostics
running in the background,.
>>> while true;show_status;sleep n;done
Syntax
show_status
Example
>>> show_status
ID
------- --------- ------------- ------------- ------------- ------------
00000001
0000002d
0000003d
00000045
00000052
>>>
Process ID
š
Program module name
Device under test
œ
Diagnostic pass count

Error count (hard and soft): soft errors are not usually fatal; hard errors
halt the system or prevent completion of the diagnostics.
ž
Bytes successfully written by the diagnostic.
Ÿ
Bytes successfully read by the diagnostic.
š
Program
Device
idle system
exer_kid tta1
nettest ewa0.0.0.2.1
memtest memory
exer_kid dka100.1.0.6
Running System Diagnostics
œ

Pass
Hard/Soft Bytes Written
0
0
0
0
0
0
43
0
0
7
0
0
424673280
0
0
0
DIGITAL Server 3300/3300R 3–15
show_status
ž
Ÿ
Bytes Read
0
1
1376
1376
424673280
0
2688512
0
0

Advertisement

Table of Contents
loading

This manual is also suitable for:

3300

Table of Contents