Memory Modules; Figure 7-17 Memory Slots On Motherboard - Digital Equipment 3300R Service Manual

Digital server
Table of Contents

Advertisement

FRU Removal and Replacement

Memory Modules

The position of the failing dual-inline memory modules (DIMMs) are reported by the
SROM power-up scripts ("Console Event Log," Chapter 2) or can be determined using the
procedures described with the memexer command (Chapter 3).
Note the following memory configuration rules when replacing memory:
At least one memory bank must contain a memory option.
A memory option consists of four DIMMs (0, 1, 2, and 3).
All DIMMs in a bank must be of the same capacity and part number.
STEP 1: RECORD THE POSITION OF THE FAILING DIMM.
STEP 2: LOCATE THE FAILING DIMM ON THE MOTHERBOARD.
STEP 3: REPLACE THE FAILING DIMMS.

Figure 7-17 Memory Slots on Motherboard

WARNING: CPU and memory modules have parts that operate at high
CAUTION: Do not use any metallic tools or implements including pencils to
7–24 DIGITAL Server 3300/3300R
Bank 1
Bank 0
temperatures.Wait 2 minutes after power is removed before
handling these modules.
releaseDIMM latches. Static discharge can damage the DIMMs.
DIMM 3
DIMM 2
DIMM 1
DIMM 0
DIMM 3
DIMM 2
DIMM 1
DIMM 0
IP00071A