Kill And Kill_Diags - Digital Equipment 3300R Service Manual

Digital server
Table of Contents

Advertisement

Running System Diagnostics

kill and kill_diags

The kill and kill_diags commands terminate diagnostics that are currently executing.
NOTE:
A serial loopback connector (12-27351-01) must be installed on the COM2
serial port for the kill_diags command to successfully terminate system tests.
The kill command terminates a specified process.
The kill_diags command terminates all diagnostics.
Syntax
kill_diags
kill [PID. . . ]
Argument:
[PID. . . ]
3–14 DIGITAL Server 3300/3300R
The process ID of the diagnostic to terminate. Use the show_status
command to determine the process ID.

Advertisement

Table of Contents
loading

This manual is also suitable for:

3300

Table of Contents