Memexer - Digital Equipment 3300R Service Manual

Digital server
Table of Contents

Advertisement

memexer

The memexer command tests memory by running a specified number of memory
exercisers. The exercisers are run in the background and nothing is displayed unless an
error occurs. Each exerciser tests all available memory in twice the backup cache size
blocks for each pass.
To terminate the memory tests, use the kill command to terminate an individual diagnostic
or the kill_diags command to terminate all diagnostics. Use the show_status display to
determine the process ID when terminating an individual diagnostic test.
Syntax
memexer [number]
Argument:
[number]
Examples
The following is an example with no errors.
>>>
memexer 4
>>>
show_status
ID
Program
--- ------------ ------------ ------ --------- ----------
00000001
000000c7
000000cc
000000d0
000000d1
>>>
kill_diags
>>>
Number of memory exercisers to start. The default is 1.
The number of exercisers, as well as the length of time for testing, depends
on the context of the testing. Generally, running three to five exercisers for
15 minutes to 1 hour is sufficient for troubleshooting most memory
problems.
Device
Pass Hard/Soft Bytes Written
idle
system
memtest
memory
memtest
memory
memtest
memory
memtest
memory
Running System Diagnostics
0
0
0
3
0
0 635651584
2
0
0 635651584
2
0
0 635651584
3
0
0 635651584
DIGITAL Server 3300/3300R 3–9
Bytes Read
0
0
62565154
62565154
62565154
62565154