2.3.1 Removing Unnecessary EW Board

2.3.2 Station Number when EW Board is Left

2
Setup
2.3

Setting and Confirmation of Hardware Configuration

Setting and Confirmation of Hardware Configuration
The WELDCOM is connected to the welding power source using the
digital interface via Ethernet communication. This does not require the EW
board (AEW01, AEW02, etc.) for an analog interface, so remove the EW
board.
In multiple robot systems, if some welding power source uses
digital interface and some uses analog interface, leave as
SUPPLE
-MENT
many EW boards as the necessary analog interfaces.
A digital interface requires a virtual EW module, not an actual EW board.
The virtual EW module also has a station number. If leaving an EW board
unremoved for other welding power sources, set the actual EW board
station number so that it does not duplicate the virtual EW module station
number.
(Setting Example)
Replacing welding power source of analog interface with that of
digital interface
 Remove the actual EW board, which will be unnecessary. (The station
number of the virtual EW module is set at the time of configuration.)
Station Number: 01
Station Number: 01
When connecting welding power source of digital interface as
Welder 1, and analog interface as Welder 2
 Because the virtual EW module station number is set to the smallest
number at the time of configuration, set the EW board station number to
the second or later number.
Station Number: 02
Station Number: 01
X100
YRC1000
AEW01
ACP01
YCP01
Virtual
Virtual
EW
EW
YRC1000
AEW01
ACP01
HW1484216
2-2
Welder1
Digital I/F
Power Source
Welder1
Digital I/F
Power Source
Welder2
Analog I/F
Power Source