YASKAWA YRC1000 Instructions Manual page 61

For weldcom function: arc welding/digital i/f function
Hide thumbs Also See for YRC1000:
Table of Contents

Advertisement

HW1484216
Alarm
Alarm
No.
Name
TPS:
4290
ERROR
6
Alarm and Error
6.1
Alarm
Sub
Meaning
Code
52
Err052
Sub code[52**] shows the error code of
Fronius power source
52 :main error code
** :sub error code
53
ErrPE
Sub code[53**] shows the error code of
Fronius power source
53 :main error code
** :sub error code
54
Err054
Sub code[54**] shows the error code of
Fronius power source
54 :main error code
** :sub error code
55
NoIGn
Sub code[55**] shows the error code of
Fronius power source
55 :main error code
** :sub error code
56
Err056
Sub code[56**] shows the error code of
Fronius power source
56 :main error code
** :sub error code
57
NoGAS
Sub code[57**] shows the error code of
Fronius power source
57 :main error code
** :sub error code
58
NoArc
Sub code[58**] shows the error code of
Fronius power source
58 :main error code
** :sub error code
59
Err059
Sub code[59**] shows the error code of
Fronius power source
59 :main error code
** :sub error code
Remedy
Mains voltage too high or NT 24
defective
Confirm the Fronius's manual
Low-resistance connection between
secondary and machine housing find
out the cause
Confirm the Fronius's manual
Increase the bbc (burn-back control)
Switch off "Wire stick " in the set-up
menu
After the end of welding, make sure
that the wire does not collide with the
workpiece when the torch is
retracted.
Confirm the Fronius's manual
Set a lower Ito value
Keep the torch stand-off distance
smaller before ignition.
Confirm the Fronius's manual
Check how much wire is left on the
spool
If necessary, change the spool
Confirm the Fronius's manual
Check what volume of gas is still
available
Confirm the Fronius's manual
Check the seam
Confirm the Fronius's manual
Confirm the Fronius's manual
HW1484216
6-7
61/79

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents

Save PDF