Optional Parameters For Fronius Tps; Optional Parameter For Froniustpsi - YASKAWA YRC1000 Instructions Manual

For weldcom function: arc welding/digital i/f function
Hide thumbs Also See for YRC1000:
Table of Contents

Advertisement

HW1484216

2.5.11 Optional Parameters for Fronius TPS

2.5.12 Optional Parameter for FroniusTPSi

2
Setup
2.5
System Configuration
Parameter
Name
-AxP96
TPS panel type forcible designation
It can change the "Select Synergic" window.
0: auto (Initial setting)
1: Standard
2: CMT
3: US
5: CMT-L
Parameter
Name
-RS380
Timeout lifecycle of welder
Timeout lifecycle of welder can be set.
Unit:10 ms
Range: 5 (50 ms) - 30 (300 ms)
If it is out of range, 10 (100 ms) will be set (initial setting).
Parameter
Name
-AxP107
Designation of switching TPSi working mode
It can change the switching rule for TPSi working mode
0: Switch to the mode selected by welding condition (Initial setting)
1: Switch the mode with following rule.
Executing a job Switch to the mode selected by welding condition
NOT Executing a job "INTERNAL" mode (fixed)
Parameter
Name
-RS380
Timeout lifecycle of welder
Timeout lifecycle of welder can be set.
Unit:10 ms
Range: 5 (50 ms) - 30 (300 ms)
If it is out of range, 10 (100 ms) will be set (initial setting).