HW1484216
Alarm
Alarm
No.
Name
4271
MOTOWELD
VOLT.DETEC
T WIRE
ERROR
4272
MOTOWELD
SAFTY-
CIRCUIT
ERROR
4273
MOTOWELD
IGBT SHORT
CIRCUIT
4274
MOTOWELD
VOLTAGE
DETECTOR
ERROR
4275
MOTOWELD
AUX.
CIRCUIT OV.
CURRENT
4276
MOTOWELD
DSP ADC
ERROR
6
Alarm and Error
6.1
Alarm
Sub
Meaning
Code
702
Sub Code: MOTOWELD's Err Code.
101
Sub Code: MOTOWELD's Err Code.
104
Sub Code: MOTOWELD's Err Code.
110
Sub Code: MOTOWELD's Err Code.
111
Sub Code: MOTOWELD's Err Code.
119
Sub Code: MOTOWELD's Err Code.
Remedy
(1)Check if the voltage detection
wire is connected.
The use of MOTOWELD-RP500/
EL350:
Check to confirm that the welding
voltage sensing cable or the short-
circuiting cap is connected to the
connector CON7.
The use of MOTOWELD welding
power source other than above:
Check to confirm that the welding
voltage sensing cable select switch is
set to "Base Metal".
(2)Check to confirm that the contact
chip and the welding work are not in
contact. Cancel the contact if any,
and weld them.
(3)Temporary power failure may
have occurred.
(4) When the welding voltage
sensing cable is used, please
connect the welding voltage sensing
cable to the base metal.
(5) When the AC unit used, a
welding power source output cable,
please confirm whether the output
cable of the wiring of the AC unit is
not a mistake.
(6) When the AC unit used, please
make sure that the power of the AC
unit is turned on.
Contact your YASKAWA
representative.
Replace the IGBT device (Part code
AJ0EL3870). Contact your
YASKAWA representative.
Contact your YASKAWA
representative.
The board may be broken. Contact
your YASKAWA representative.
Contact your YASKAWA
representative.
HW1484216
6-19
73/79