YASKAWA YRC1000 Instructions Manual page 31

For weldcom function: arc welding/digital i/f function
Hide thumbs Also See for YRC1000:
Table of Contents

Advertisement

HW1484216
Item
POWER SOURCE IP
ADDRESS
VOLT.CMD.:REGIST.ADDR.
CURR.CMD.:REGIST.ADDR.
SAMPLING
VOLT.:REGIST.ADDR.
SAMPLING.
CURR.:REGIST.ADDR.
SAMPLING W.F.S.:
REGIST.ADDR.
FEEDER MTR.
CURR.:REGIST.ADDR.
SHORT-CIRCUIT
CNT.:REGIST.ADDR.
MAIN ERROR
CODE:REGIST.ADDR.
SUB ERROR
CODE:REGIST.ADDR.
OPERATION
MODE:REGIST.ADDR.
TPS JOB#:REGIST.ADDR.
PROGRAM#:REGIST.ADDR.
TCP SPEED FUNCTION
RCU5000 PENDANT
2
Setup
2.5
System Configuration
Contents
Sets the IP address of the welding power source.
E.g.) When the IP address is 192.168.255.211
AxP76=192, AxP77=168, AxP78=255, AxP79=211
Sets the welding voltage command output register
address.
The values that can be set in the register address are
as follows.
-1:
Processing is invalid.
0 - 399:
General register number
The unit of the voltage command to be output is 0.1 V.
Sets the welding current command output register
address.
The values that can be set in the register address are
as follows.
-1:
Processing is invalid.
0 - 399:
General register number
The unit of the current command to be output is 0.1 A.
Sets the register address for the sampling welding
voltage value.
Sets the register address for the sampling welding
current value.
Sets the register address for the sampling welding
feeder speed value output.
Sets the register address for the sampling welding
feeder load (feeding motor current) value output.
The unit of the feeder load to be output is 0.1 A.
Sets the register address for the welding short-circuit
count output.
Sets the main error code input register address.
Sets the sub error code input register address.
Sets the operation mode input register address.
Sets the job number output register address.
Sets the program number input register address.
Sets whether the TCP speed function is VALID or
INVALID.
The values that can be set in the register address are
as follows.
0: INVALID
1: VALID
Sets whether the RCU5000 pendant is USED or NOT
USED.
The values that can be set in the register address are
as follows.
0. NOT USED
(The JOB number can be set within the range of 0 to 99.)
1. USED
(The JOB number can be set within the range of 0 to 999.)
2-20
Parameter Initial
AxP76
AxP77
AxP78
AxP79
AxP60
AxP61
AxP147
AxP148
AxP81
AxP82
AxP83
AxP85
AxP86
AxP87
AxP88
AxP89
AxP90
AxP91
HW1484216
value
192
168
255
210
150
151
152
153
NO USE
NO USE
NO USE
NO USE
NO USE
156
155
154
INVALID
NOT
USED
31/79