Froniustpsi Type: Operation Of Select Synergic Window; Froniustpsi Type: Operation Of Weld Parameter Setting Window - YASKAWA YRC1000 Instructions Manual

For weldcom function: arc welding/digital i/f function
Hide thumbs Also See for YRC1000:
Table of Contents

Advertisement

3
Operation of Welding Condition File Edit Window

3.12 FroniusTPSi Type: Operation of Select Synergic Window

3.12
FroniusTPSi Type: Operation of Select Synergic Window
1. At the top window, select a weld user file, and then select {Select Synergic}.
2. Select the welding condition.
– Select a value for "Mode", "Material type", "Diameter", and "Gas Type".
3. Select a welding program to be used, and then press {OK}.
3.13
FroniusTPSi Type: Operation of Weld Parameter Setting
Window
1. At the top window, select {Set Parameter}.
– The parameter of the selected weld user file can be changed.
2. Select {Weld Parameter}.
Penetration stabilizer: Sets the allowable value of speed fluctuation in
fluctuating the wire feeding speed in order to stabilize the welding current.
It is available only when the welding mode is PMC or LSC.
Arc length stabilizer: Stabilizes welding even if the amount of wire stickout
for short circuiting arc varies or there is interference from the outside.
It is available only when the welding mode is PMC.
For details, see the user manual of the welding power source.