SUB MENU
MAIN MENU
ATW SETUP
QUIT
ATW DAY MODE
ATW NIGHT MODE
ATW SPEED
START UP TIME
START CC FILTER
C.TEMP SETTING RED
RED LIMIT AUTO SET
RED LIMIT CONTROL
RED LIMIT INIT
C.TEMP SETTING BLUE
BLUE LIMIT AUTO SET
BLUE LIMIT CONTROL
BLUE LIMIT INIT
ATW REFERENCE
ATW RED REFERENCE
ATW BLUE REFERENCE
NOISE FILTER
QUIT
STEP GAIN
NOISE FILTER
AUTO HOLD IRIS
-
EXIT
-
****** ENGINEER PAGE1
SELECT
DEFAULT
-
-
Moves from the sub menu to the main menu.
PRESET, NORMAL
PRESET
ATW allowable range at AVC OFF, AVC DAY MODE.
PRESET, NORMAL
NORMAL
ATW allowable range at AVC NIGHT MODE.
1 to 10
2
Sets the speed of the ATW correction.
1 to 5
OFF
Sets the response speed of correction against the change of the subject.
A(3200), B(5600)
B(5600)
Sets the position of the CC filter when ATW is turned on.
QUIT
Moves to ATW SETUP menu.
ON, OFF
OFF
Sets the correction range of R ch.
-100 to +100
0
The value for determining the correction range of R ch.
ON, OFF
OFF
Sets back to the correction range of the factory setup value.
QUIT
Moves to ATW SETUP menu.
ON, OFF
OFF
Sets the correction range of B ch.
-100 to +100
0
The value for determining the correction range of B ch.
ON, OFF
OFF
Sets back to the correction range of the factory setup value.
QUIT
Moves to ATW SETUP menu.
-100 to +100
0
Sets the standard value of the R ch level.
-100 to +100
0
Sets the standard value of the B ch level.
-
-
Moves from the sub menu to the main menu.
-6, -3, 0, 3, 6, 9,
0dB
Sets NOISE FILTER level to each gain. But only OFF can be set from -6
12, 18, 24, 30, 36,
to +12dB.
42, 48, 54dB
OFF, LOW, MID, HIGH
OFF
Selects NOISE FILTER level.
HOLD, MANUAL, AUTO
AUTO
IRIS operation at AUTO HOLD.
-
-
Turns off the menu.
5. OPERATION
(2/2) ******
FUNCTION
5 - 35