Notice
Before shipment, the ENGINEER SET FILE data is the same as
the FACTORY data.
The ENGINEER SET FILE data is overwritten by executing the
engineer menu ENGINEER SET FILE RENEW.
Notice
When the data loading of ENGINEER and FACTORY is executed,
the display may licker for a few seconds.
■ WARNING
QUIT
DC INPUT WARN
BATT VOLT WARN
TEMP WARN
FAN WARN
DC INPUT WARN
BATT VOLT WARN
TEMP WARN
FAN WARN
WARNING
OK
12.0V
OK
OK
OK
: Displays the voltage state for the +12V power input. Also
displays the voltage value.
OK: The input voltage is normal.
NG: The input voltage is abnormal.
: Displays the voltage state of the battery for the backup of the
MPU module.
OK: The battery voltage is normal.
NG: The battery voltage is abnormal.
: Displays the temperature state inside the CCU.
OK: The internal temperature is normal.
NG: The internal temperature is abnormal.
: Displays the rotational state of the CCU fan.
OK: The fan rotation is normal.
NG: The fan rotation is abnormal.
5. OPERATION
(OK, NG) Input voltage display
(OK, NG)
(OK, NG)
(OK, NG)