5
Query OBW
:MEASure:OBW:XDB?
Use this command to query the occupied bandwidth
according to the method you set.

ACPR Subsection

Center Freq
:MEASure:ACPR:CENTer <freq>
:MEASure:ACPR:CENTer?
Sets the center frequency of the main channel power.
Main channel
:MEASure:ACPR:MAIN <freq>
:MEASure:ACPR:MAIN?
Specifies the range of integration used in calculating the
power in the main channel. Use the knob and the arrow
keys to set the bandwidth.
Adjacent channel
:MEASure:ACPR:ADJacent <freq>
:MEASure:ACPR:ADJacent?
Specifies the range of integration used in calculating the
power in the adjacent channel. Use the knob and the arrow
keys to set the bandwidth.
N9340B Programmer's Guide