A.2.6
G395-250 to G395-450, liquid cooling
Designation
Technical data
Output, motor side
1)
Voltage
3)
Rated current, effective (l
)
N
Peak current
Rotating field frequency
Switching frequency of the power stage
Input, mains side
Mains voltage
Device connected load (with mains choke)
Current
(with mains choke)
1)
Asymmetry of mains voltage
Frequency
Power dissipation at I
1)
N
DC link
Capacitance
Brake chopper switch-on threshold
1)
Data referred to mains voltage 3 x 400 V
and switching frequency of the power stage 4 kHz
eff
2)
When designing the drive, it is to be taken into account that the maximum output voltage reduces as a function of the active power.
3)
Connection of an ext. braking resistor to devices with int. braking resistor not permitted (model G395-xxx-xxx-xx2)!
4)
Cooling performance adequate also with optional internal braking resistor
Table A.14 Technical data G395-250 to G395-450 liquid cooling
moog
ID no.: CA65642-001 06/2018
3-phase U
Mains
250 A
325 A
450 A
See A.1.6
0 ... 400 Hz
2, 4 kHz (8, 12, 16)
2)
(3 x 230 V/ 3 x 400 V/ 3 x 460 V/ 3 x 480 V) ±10 %
173 kVA
225 kVA
310 kVA
250 A
325 A
450 A
±3 % maximum
50/60 Hz ±10 %
3960 W
4800 W
6750 W
3600 µF
5400 µF
7200 µF
820 V DC
Designation
Technical data
Minimum ohmic resistance of an externally installed
braking resistor
Brake chopper peak power
with external braking resistor
Option: internal braking resistor
Brake chopper continuous power
with internal braking resistor
Brake chopper peak power
with internal braking resistor
Chiller data
Coolant pressure
(rated value / maximum value)
Coolant flow rate
4)
(rated value / maximum value)
The coolant temperature can be between +5 °C (+41 °F) and
+40 °C (+104 °F). However, the coolant temperature should
Feed coolant temperature
not be more than 10 °K below the ambient temperature to
prevent condensation on the heat sink.
1)
Data referred to mains voltage 3 x 400 V
and switching frequency of the power stage 4 kHz
eff
2)
When designing the drive, it is to be taken into account that the maximum output voltage reduces as a function of the active power.
3)
Connection of an ext. braking resistor to devices with int. braking resistor not permitted (model G395-xxx-xxx-xx2)!
4)
Cooling performance adequate also with optional internal braking resistor
Table A.14 Technical data G395-250 to G395-450 liquid cooling
MSD Single-Axis System Operation Manual AC-AC Servo Drive
3.2 Ω
3)
2.5 Ω
3)
1.7 Ω
3)
210 kW
269 kW
395 kW
3.3 Ω
2.4 Ω
5000 W
6800 W
204 kW
280 kW
1 / 2 bar
11 / 13 l per min
77
Need help?
Do you have a question about the MSD and is the answer not in the manual?
Questions and answers