G392-020 To G392-072, Air Cooling - Moog MSD Operation Manual

Ac-ac servo drive
Hide thumbs Also See for MSD:
Table of Contents

Advertisement

A.2.2

G392-020 to G392-072, air cooling

Designation
Technical data
Output, motor side
1)
Voltage
2)
Rated current, effective (l
)
20 A
n
Peak current
Rotating field frequency
Switching frequency of the power stage
Input, mains side
Mains voltage
(3 x 230 V/ 3 x 400 V/ 3 x 460 V/ 3 x 480 V) ±10 %
Device connected load
1)
15 kVA
(with mains choke)
Current
1)
(with mains choke)
21.6 A
Asymmetry of mains voltage
Frequency
Power dissipation at I
1)
400 W
N
DC link
Capacitance
1230 µF
Brake chopper switch-on threshold
1)
Data referred to mains voltage 3 x 400 V
and switching frequency of the power stage 8 kHz
eff
2)
When designing the drive, it is to be taken into account that the maximum output voltage reduces as a function of the active power.
3)
Connection of an ext. braking resistor to devices with int. braking resistor not permitted (model G392-xxx-xxx-xx2/xx4)!
Table A.10 Technical data, G392-020 to G392-072, air cooling
moog
ID no.: CA65642-001 06/2018
3-phase U
Mains
24 A
32 A
45 A
60 A
72 A
See A.1.2
See A.1.3
0 ... 400 Hz
4, 8, 12, 16 kHz
18.2 kVA
24.2 kVA
31.2 kVA
41.0 kVA
50 kVA
26.2 A
34.9 A
45 A
60 A
72 A
±3 % maximum
50/60 Hz ±10 %
475 W
515 W
610 W
830 W
1010 W
2000 µF
430 µF
900 µF
650 V DC
1)
820 V DC
Designation
Technical data
Minimum ohmic resistance of an
20 Ω
3)
externally installed braking resistor
Brake chopper peak power
21 kW
1)
with external braking resistor
Optional:
Internal braking resistor
See "Table 4.21 Data on the
Brake chopper peak power
integrated braking resistor (model
with internal braking resistor
G392-xxx-xxx-xx2/xx4 and G395-
xxx-xxx-xx2/xx4)"
1)
Data referred to mains voltage 3 x 400 V
and switching frequency of the power stage 8 kHz
eff
2)
When designing the drive, it is to be taken into account that the maximum output voltage reduces as a function of the active power.
3)
Connection of an ext. braking resistor to devices with int. braking resistor not permitted (model G392-xxx-xxx-xx2/xx4)!
Table A.10 Technical data, G392-020 to G392-072, air cooling
NOTE:
For more information on the brake chopper also refer to chapter "4.16 Braking
resistor (RB)"
MSD Single-Axis System Operation Manual AC-AC Servo Drive
12 Ω
18 Ω
13 Ω
3)
35 kW
37 kW
52 kW
1)
90 Ω
-
-
73