moog
ID no.: CA65642-001 06/2018
A.2.3
G392-090 to G392-170, air cooling
Designation
Technical data
Output, motor side
1)
Voltage
2)
Rated current, effective (l
)
n
Peak current
Rotating field frequency
Switching frequency of the power stage
Input, mains side
Mains voltage
Device connected load
1)
(with mains choke)
Current
(with mains choke)
1)
Asymmetry of mains voltage
Frequency
Power dissipation at I
1300 W
1)
N
DC link
Capacitance
1060 µF
Brake chopper switch-on threshold
Minimum ohmic resistance of an externally
installed braking resistor
1)
Data referred to mains voltage 3 x 400 V
and switching frequency of the power stage 8 kHz
eff
2)
When designing the drive, it is to be taken into account that the maximum output voltage reduces as a function of the active power.
Table A.11 Technical data, G392-090 to G392-170, air cooling
3-phase U
Mains
90 A
110 A
143 A
170 A
See A.1.3
0 ... 400 Hz
4, 8, 12, 16 kHz
(3 x 230 V/ 3 x 400 V/ 3 x 460 V/ 3 x 480 V) ±10 %
62 kVA
76 kVA
99 kVA
118 kVA
90 A
110 A
143 A
170 A
±3 % maximum
50/60 Hz ±10 %
1600 W
2100 W
2500 W
2120 µF
3180 µF
4240 µF
820 V DC
12 Ω
10 Ω
8.5 Ω
6.5 Ω
MSD Single-Axis System Operation Manual AC-AC Servo Drive
Designation
Technical data
Brake chopper peak power
with external braking resistor
Optional:
Internal braking resistor
Brake chopper peak power
with internal braking resistor
1)
Data referred to mains voltage 3 x 400 V
and switching frequency of the power stage 8 kHz
eff
2)
When designing the drive, it is to be taken into account that the maximum output voltage reduces as a function of the active power.
Table A.11 Technical data, G392-090 to G392-170, air cooling
NOTE:
For more information on the brake chopper and braking resistors also refer to
chapter "4.16 Braking resistor (RB)"
56 kW
67 kW
79 kW
103 kW
-
-
-
-
-
-
-
-