Electrical installation
moog
ID no.: CA65642-001 06/2018
DANGER! Risk of injury due to electrical power!
• Carelessness will result in serious injuries or death.
Never make or disconnect electrical connections while they are electrically live! Always disconnect
the power before working on the device. Even 10 min. after switching off the mains supply,
dangerously high voltages of ≥50 V may still be present (capacitor charge). So check that
electrical power is not present!
Terminal L+ (Size 1 to Size 4) or BR+ (Size 5 to Size 7) is permanently connected to DC link
potential (>300 V DC). The connection is not protected internally in the device.
WARNING!
Risk of injury due to hot surfaces on the ext. braking resistor!
• Carelessness may result in serious burns.
The braking resistor heats up very significantly during operation and can reach temperatures of
up to +250 °C (+482 °F). On touching there is a risk of serious burns to the skin.
CAUTION! Damage to the external braking resistor due to lack of tempera-
ture monitoring!
• Carelessness can result in overheating of the ext. braking resistor!
The external braking resistor must be monitored by the controller. The temperature of the
braking resistor is monitored by a temperature sensor (Klixon). In the event of overheating the
servo drive must be disconnected from the mains supply.
MSD Single-Axis System Operation Manual AC-AC Servo Drive
Available braking resistors (excerpt)
Order
Continuous
Resistance
designation
braking power
CB09047-001
35 W
CB09048-001
150 W
200 Ω
CB09049-001
300 W
CA59737-001
35 W
CA59738-001
150 W
90 Ω
CA59739-001
300 W
CA59740-001
1000 W
CA59741-001
35 W
CA59742-001
150 W
26 Ω
CA59743-001
300 W
CA59744-001
1000 W
CB36901-001
300 W
20 Ω
CB36902-001
300 W
15 Ω
1) Tolerance ±10 %
2) Is the maximum possible braking power depending on the ON-time and cycle time
Table 4.22 Technical data - braking resistors
NOTE:
You will find the exact specifications of the braking resistors, in particular the
surface temperature, the maximum supply voltage and the dielectric strength
at high voltages in the MSD Servo Drive Ordering Catalog.
Please consult your project engineer for more detailed information on the design of
braking resistors.
48
Peak braking
1)
Protection
Figure
2)
power
2800 W
IP54
2800 W
IP54
2800 W
IP54
6250 W
IP54
6250 W
IP54
6250 W
IP54
6250 W
IP65
21600 W
IP54
21600 W
IP54
Example:
CB09047-001
21600 W
IP54
21600 W
IP65
27750 W
IP54
37000 W
IP54
Need help?