Current Carrying Capacity Size 3 To Size 4, Liquid Cooling - Moog MSD Operation Manual

Ac-ac servo drive
Hide thumbs Also See for MSD:
Table of Contents

Advertisement

moog
 ID no.: CA65642-001 06/2018
A.1.4

Current carrying capacity Size 3 to Size 4, liquid cooling

NOTE:
The shutdown temperature for liquid-cooled devices is +65 °C (+149 °F) (internally at the heat sink). The servo drive is shut down and is
only ready for operation again after a short cooling phase.
Switching
frequency
Ambient
of the
temperature
Servo drive
Rated current
power
stage
[kHz]
[°C]/[°F]
+45
4
(+113)
8
G395-016 (Size 3)
+40
12
(+104)
16
+45
4
(+113)
8
G395-020 (Size 3)
+40
12
(+104)
16
+45
4
(+113)
8
G395-024 (Size 4)
+40
12
(+104)
16
4
8
+40
G395-032 (Size 4)
(+104)
12
16
All data apply for a motor cable length ≤10 m (32.80 ft).
1)
Shutdown as per I²t characteristic
2)
Permissible peak current at maximum 70 % initial load
Table A.5 Rated and peak current, Size 3 and Size 4 (liquid cooling)
At mains voltage 400 V
At mains voltage 460 V
Peak current
Rated current
[A
]
eff
[A
]
0 Hz to >5 Hz
[A
]
eff
eff
16
32
16
16
32
13.9
11
22
8.8
8
16
5.9
20
40
20
20
40
17.4
13.8
27.6
11
10
20
7.4
24
48
24
24
48
21
15.8
31.6
12.4
11.3
22.6
9.2
32
64
32
32
64
28
21
42
16.5
15
30
12.2
MSD Single-Axis System Operation Manual AC-AC Servo Drive
At mains voltage 480 V
Peak current
Peak current
Rated current
[A
]
[A
]
eff
eff
0 Hz to >5 Hz
[A
]
0 Hz to >5 Hz
eff
32
16
32
27.8
13.3
26.6
17.6
8
16
11.8
5.2
10.4
40
20
40
34.8
16.6
33.2
22
10
20
14.8
6.5
13
48
24
48
42
20
40
24.8
11.3
22.6
18.4
8.4
16.8
64
32
64
56.0
26.7
53.4
33
15
30
24.4
11.2
22.4
Overload
For
factor
time
1)
≥ 5 Hz
[%]
[s]
200
10
200
10
200
10
200
10
68