Extron electronics IN1804 Series User Manual page 68

Scaling presentation switchers scalers
Hide thumbs Also See for IN1804 Series:
Table of Contents

Advertisement

Command
Input Configuration (continued)
Auto-input Switch Mode
Set the auto-input switch
mode
View auto-input switch
mode
Set user priority order for
auto-input switch mode 1
NOTE:
The Set Priority command returns an E13 error code unless the correct number of
View mode 1 priority order
Set timeout
View timeout
KEY:
X3)
= Auto-input switch mode
X3!
= Input number for setting user priority
X3@
= Auto-input switch timeout
Picture Adjustments
Freeze
Enable
Disable
View
KEY:
X1)
= On or Off status
ASCII Command
Response
(Host to Scaler)
(Scaler to Host)
EX3)
}
AUSW
Ausw
E
}
X3)]
AUSW
E
X3!
X3!
X3!
}
P
•...•
AUSW
AuswP
E
}
X3!
O AUSW
E
X3@
}
T
AUSW
AuswT
E
}
X3@]
TAUSW
1*1F
Frz1*1
1*0F
Frz1*0
X1)]
1F
IN1804 Scaling Presentation Switcher • SIS Configuration and Control
Additional Description
X3)]
Set the auto-input switch mode to
View current auto-input switch mode
X3)
.
X3!
X3!
X3!]
Set the input priority switching order,
•...•
highest priority (first) to lowest (last).
X3!
X3!]
View the order in which the inputs will
•...•
be selected in auto-input switch mode
1 (highest to lowest priority).
X3@]
Set the amount of time without video to
switch to the previous input.
View the auto-input switch timeout
duration in seconds.
0 = Disabled — Manual switching (default)
1 = User-defined priority mode — The scaler selects the
input to which the user assigns priority. If no priority is
assigned, the scaler selects the active input with the
highest number.
2 = Last connected mode — The scaler selects the
most recently applied input, and retains a history of the
order in which active inputs are connected to the unit. If an
active input is removed, the scaler switches to the most
recently prioritized input.
Arrange input numbers in user priority order.
1 = input 1, 2 = input 2, 3 = input 3, 4 = input 4
Amount of time without video that elapses before switching to
the input with the next priority.
1 through 500 (in 1-second increments, default = 3 seconds)
0 = Immediately switch to the input with the next priority if the
current input is removed.
]
Freeze the output on the screen.
]
Unfreeze the output.
Show the freeze status of the output.
0 = Off or disabled
1 = On or enabled (default)
X3)
.
X!
variables are entered.
60

Advertisement

Table of Contents
loading

Table of Contents