Assignment Of The Feedback And Control Interfaces For The Measurement Modes - Siemens SIMATIC ET 200S Operating Instructions Manual

Hide thumbs Also See for SIMATIC ET 200S:
Table of Contents

Advertisement

2.7.11
Assignment of the Feedback and Control Interfaces for the Measurement
Modes
Note
For the 1Count24V, the following data of the control and feedback interface are consistent:
Bytes 0 to 3
Bytes 4 to 7
Bytes 8 to 11 (modified user data interface)
Use the access or addressing mode for data consistency over the entire control and
feedback interface on your master (only for configuration using the GSD file).
Assignment Tables
Table 2- 17
Feedback Interface (Inputs)
Address
Assignment
Bytes 0 to 3
Measured value
Byte 4
Bit 7:
Bit 6:
Bit 5:
Bit 4:
Bit 3:
Bit 2:
Bit 1:
Bit 0:
Byte 5
Bit 7:
Bit 6:
Bit 5:
Bit 4:
Bit 3:
Bit 2:
Bit 1:
Bit 0:
Byte 6
Bit 7:
Bit 6:
Bit 5:
Bit 4:
Bit 3:
Bit 2:
Bit 1:
Bit 0:
Byte 7
Reserve = 0
Bytes 8 to 11
Count value
Modified user data interface
1
Technological Functions
Operating Instructions, 06/2010, A5E00124867-07
Short circuit of the encoder supply
Short circuit / wire break / overtemperature
Parameter assignment error
Reserve = 0
Reserve = 0
Resetting of status bits active
Load function error
Load function is running
Down direction status
Up direction status
Reserve = 0
Reserve = 0
DO1 status
Reserve = 0
DI status
Internal gate status
Reserve = 0
Low limit of measuring range
High limit of measuring range
Reserve = 0
Measurement completed
Reserve = 0
Reserve = 0
Reserve = 0
1
1Count24V
2.7 Measurement Modes
Designation
ERR_24V
ERR_DO1
ERR_PARA
RES_STS_A
ERR_LOAD
STS_LOAD
STS_C_DN
STS_C_UP
STS_DO1
STS_DI
STS_GATE
STS_UFLW
STS_OFLW
STS_CMP1
75

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents