2PULSE
5.8 Technical Specifications of the 2PULSE, Terminal Assignment
General technical specifications
Data for the Digital Outputs
Output voltage
Output current
Measurement of current
Minimum pulse duration
Accuracy
Output delay (with resistive load)
Lamp load
Control of a digital input
Switching frequency
Limitation (internal) of the inductive circuit
interruption voltage
Short circuit protection for output
Cable lengths
Status, Interrupts, Diagnostics
Status indicators
Diagnostic functions
Polarity reversal can lead to the digital outputs being switched through.
1)
See the figures below
2)
With a load of ≤ 50 Ω
3)
Asymetrical edge slopes appear to be a higher percentage when switching the outputs on and
4)
off at higher frequencies
348
with "1" signal
with "1" signal
Rated value
Permitted Range
With "0" signal (residual current)
Accuracy
In compatibility mode
At "1" to "0" transitions
At "1" to "0" transitions
4 )
Response threshold
Unshielded
Shielded
Group error
Diagnostic information readable
Minimum L+ - 1 V
2 A
(4 A at parallel connection)
2)
7 mA...2 A
max. 0.1 mA
Yes, in the "Pulse width modulation" and "Pulse
train" operating modes
3 %
100 µs
200 µs
± (period duration x 100 ppm) ±100 µs
max. 100 µs
max. 200 µs
Maximum 10 W
Yes
Up to 5 kHz
Take the technical specifications of your
connected load into consideration.
L+ -(50 V ... 65 V)
Yes
Typ. 10 A to 16 A
600 m
1000 m
Green LED for DI 0, DI 1, DO 0, DO 1
Red LED "SF"
Yes