2.7.11

Assignment of the Feedback and Control Interfaces for the Measurement Modes

Note
The following data of the control and feedback interfaces are consistent for the
1Count24V/100kHz:
Bytes 0 to 3
Bytes 4 to 7
Bytes 8 to 11 (modified user data interface)
Use the access or addressing mode for data consistency over the entire control and
feedback interface on your master (only for configuration using the GSD file).
Assignment Tables
Table 2-17
Feedback Interface (Inputs)
Address
Assignment
Bytes 0 to 3
Measured value
Byte 4
Bit 7:
Bit 6:
Bit 5:
Bit 4:
Bit 3:
Bit 2:
Bit 1:
Bit 0:
Byte 5
Bit 7:
Bit 6:
Bit 5:
Bit 4:
Bit 3:
Bit 2:
Bit 1:
Bit 0:
Technological Functions
Operating Instructions, 02/2007, A5E00124867-05
Short circuit of the encoder supply
Short circuit / wire break / overtemperature
Parameter assignment error
Reserve = 0
Reserve = 0
Resetting of status bits active
Load function error
Load function is running
Down direction status
Up direction status
Reserve = 0
Reserve = 0
DO1 status
Reserve = 0
DI status
Internal gate status
1Count24V/100kHz
2.7 Measurement Modes
Designation
ERR_24V
ERR_DO
ERR_PARA
RES_STS_A
ERR_LOAD
STS_LOAD
STS_C_DN
STS_C_UP
STS_DO1
STS_DI
STS_GATE