Mounting and installation
1
Service interface
Fig. 3.5
Bus node (as an example at the bus node CPX-FB33)
3.5.3
Selecting the power supply unit
Warning
For the electrical power supply, use only PELV circuits in accordance with
IEC 60204-1/EN 60204-1 (Protective Extra-Low Voltage, PELV).
Also take into account the general requirements for PELV circuits in accordance with
IEC 60204-1/EN 60204-1.
Use only voltage sources that ensure a reliable electric separation of operating
voltage from the network in accordance with IEC 60204-1/EN 60204-1.
Through the use of PELV circuits, protection from electric shock (protection from direct and indirect
contact) is ensured in accordance with IEC 60204-1/EN 60204-1 (refer to Electrical Equipment of Ma
chines. General Requirements).
Note
Use regulated power supplies to ensure that the load voltage of the outputs always
remains within the permitted tolerances during operation (è Chapter 3.5.4).
Make sure that the selected power supply units provide sufficient power.