Festo CPX-FB6 Manual page 46

Cpx fieldbus node
Hide thumbs Also See for CPX-FB6:
Table of Contents

Advertisement

2. Commissioning
1)
Electric modules
Bus node FB6, remote I/O,
without system diagnostics
Bus node FB6, remote I/O,
3)
with status bits
Bus node FB6, remote I/O,
with I/O diagnostics interface
Bus node FB6, remote controller,
without system diagnostics
Digital 4-off input module
Digital 8-off input module
Digital 8-off input module with channel
diagnostics
Digital 8-off input module n-switching
Digital 16-off input module
Digital 16-off input module with channel
diagnostics
Digital multi I/O module
1)
Additional modules in preparation.
2)
Module indicators on the handheld; in the case of I/O modules these are shown in the inspection
window.
3)
The status bits or the I/O diagnostics interface is activated by a DIL switch (see section 1.2).
Tab. 2/2:
Overview of indicators and addresses of electric modules (part 1)
2-6
On the basis of the module type, you can ascertain the num-
ber of inputs and outputs occupied by the module.
The individual modules are displayed with their indicator on
the handheld. In the case of the I/O modules, the indicator is
also shown in the LED inspection window.
Type
CPX-FB6
3)
3)
CPX-FB6
CPX-4DE
CPX-8DE
CPX-8DE-D
CPX-8NDE
CPX-16DE
CPX-16DE-D
CPX-8DE-8DA
Module
Assigned
2)
indicator
addresses
Inputs
FB06-RIO
8 I
16 I
FB06-RC
4DI
4 I
8DI
8 I
8DI-D
8 I
8NDI
8 I
16DI
16 I
16DI-D
16 I
8DI/8DO
8 I
Festo P.BE-CPX-FB6-EN en 1207c
Outputs
16 O
8 O

Advertisement

Table of Contents
loading

Table of Contents