Festo CDVI-DN Description page 62

Valve terminal
Hide thumbs Also See for CDVI-DN:
Table of Contents

Advertisement

3. Installation
1
1
0
3
2
1214
12 14
1
4-valve manifold block
2
2-valve Bi-expansion block
3
2-valve Mo-expansion block
4
1-valve Bi-expansion block
Fig. 3/6: Example: Address assignment of the CDVI with MP connection
3-24
In the case of valves with two solenoids coils, solenoid
coil 14 occupies the less significant address and solenoid
coil 12 occupies the higher-value address.
In the case of valves with only one solenoid coil, the
higher-value address remains unused.
The following diagram shows the addressing sequence using
the example of the CDVI with 9 valve positions.
2
5
7
4
6
9
8
11
10
12 14
1214
1214
7
3
4
5
15
14
12
13
1214
14
6
5
Addresses of the solenoid coils
6
Vacant position on Mo-expansion block
(occupies 1 address)
7
Vacant position on 4-valve manifold
block (occupies 2 addresses)
Festo P.BE-CDVI-EN en 1202e