16.
Click Create to add a new handler rule. This function allows you to choose the
desired uplink fields and supports the parse script option that helps you parse
the raw data received from the sensor node as shown in Figure 4.13.
Figure 4.12 LoRaWAN Server > Backends > Handlers > Create
Item
Application
Uplink Fields
Payload
Parse Uplink
Parse Event
Build Downlink
WISE-6610 Series User Manual
Description
Enter the name of the handler.
Enter the filter values to be forwarded to the backend connector.
Enter the filter values as the format for automatic decoding.
Enter the string to extract additional data fields from the uplink frame.
See Figure 4.13 for references.
Enter the string to be forwarded to the backend connector.
Enter the string to create a downlink frame based on backend data
fields.