15.
Click Backends > Handlers to enter the Handlers List page.
The WISE-6610 Series handler is created by default. The LoRaWAN data
comes with the item with the Field in the handler settings.
Figure 4.11 LoRaWAN Server > Backends > Handlers
Field
Type
app
String
devaddr
Hex String
deveui
Hex String
appargs
Any
battery
Integer
fcnt
Integer
port
Integer
data
Hex String
datetime
ISO 8601
freq
Number
datr
String
codr
String
best_gw
Object
mac
Hex String
lsnr
Number
rssi
Number
all_gw
Object
Definition
Application (Handler) name
DevAddr of the active node
DevEUI of the device
Application arguments for the node
Most recent battery level reported by the device
Received frame sequence number
LoRaWAN port number
Raw application payload encoded as a hexadecimal string
Timestamp using the server clock
RX central frequency in MHz (unsigned float/ Hz precision)
LoRa data rate identifier (e.g. SF12BW500)
LoRa ECC coding rate identifier (default: 4/5)
Gateway with the strongest reception
MAC address of the gateway with the strongest reception
LoRa uplink SNR ratio in dB (signed float/ 0.1 dB precision)
(same as rxq.lsnr for best_gw)
RSSI in dBm (signed integer/ 1 dB precision) (same as
rxq.rssi for best_gw)
List of all gateways that received the frame