Canon Color iR C3480 Service Manual page 586

Table of Contents

Advertisement

Code
Main Cause/Detail of Detection
***: Finisher-Z1 ****: Finisher-Y1, Saddle Finisher-Y2 *****: Puncher Unit
48XX CPU lock was detected at activation.
4831 CPU was locked at activation when ASIC initialization was performed for
each main controller PCB (Sub SJ-A/PDRM-EF-A/RO-A).
4837 CPU was locked at activation when ASIC initialization was performed for
each main controller PCB (Sub SJ-A/PDRM-EF-A/RO-A).
4838 CPU was locked at activation when ASIC initialization was performed for
each main controller PCB (Sub SJ-A/PDRM-EF-A/RO-A).
4854 CPU was locked at activation when ASIC initialization was performed for
each main controller PCB (Sub LAN-bar).
4883 The CPU path was locked at activation when initialization was performed for
the main controller PCB (Sub RB-A) board.
4894 CPU was locked at activation when ASIC initialization was performed for
each main controller PCB (Sub SJ-A/PDRM-EF-A/RO-A).
4910 A board different from the main controller PCB for the machine was detected. Replace the main controller PCB.
E749
Restart in accordance with a change of the product configuration
0001 The BootROM is replaced with a different type (when the PDL option is
installed) .
0003 Replaced with other kind of BootROM (e.g. at installation of mAccele
accessory)
E804
Controller fan error
0000 Stop of power supply cooling fan was detected
0001 Stop of power supply cooling fan 2 was detected
0004 Stoppage of the controller fan is detected for 16 sec continuously.
E805
Fan error
0001 Lock fails to be detected for 5sec continuously while the exhaust fan (front) is
driven.
Disconnection of the fan connector. Lock signal fails to be sent due to a fan
failure.
0002 Lock fails to be detected for 5sec continuously while the exhaust fan (rear) is
driven.
Disconnection of the fan connector. Lock signal fails to be sent due to a fan
failure.
E806
Error in fan of main body
0001 Error in delivery adhesive fan was detected
0002 The drop of connector of delivery adhesive fan / the disconnection was
detected
0003 Error in secondary transfer exhaust fan was detected
E807
Error in fan of process cartridge
0001 Error in fan (front) of process cartridge was detected
0002 Error in fan (rear) of process cartridge was detected
E808
Error in low-voltage power supply PCB (error in zero cross)
0000 Error in low-voltage power supply PCB
E811
Error in detection of new drum unit
0000 Error in blowout of fuse for detection of new drum unit (process cartridge)
0001 Error in blowout of fuse for detection of new drum unit (process cartridge)
E840
Fan shutter error
0000 Fan shutter open/close operation Error
Cause
Abnormal rotation of the fan shutter motor
Defect of the fan shutter position sensor
Defect of the fan shutter home position error
Defect of the DC controller PCB
Countermeasures
Remove and insert the main controller PCB (Sub RB-A).
Remove and insert the DDR-SDRAM. Replace the controller
PCB (Main).
When any of 4831, 4837, 4838, 4883, 4894, or 4854 occurred,
perform the measures shown above after performing the
following measures.
Remove and insert each main controller PCB (Sub SJ-A/
PDRM-EF-A/RO-A). Clean the terminal. Replace the
controller.
Remove and insert each main controller PCB (Sub SJ-A/
PDRM-EF-A/RO-A). Clean the terminal. Replace the
controller.
Remove and insert each main controller PCB (Sub SJ-A/
PDRM-EF-A/RO-A). Clean the terminal. Replace the
controller.
Remove and insert each main controller PCB (Sub LAN-bar).
Clean the terminal. Replace the controller.
Remove and insert the RB board. --> Replace the RB board. --
> Replace the main board.
Remove and insert each main controller PCB (Sub SJ-A/
PDRM-EF-A/RO-A). Clean the terminal. Replace the
controller.
Turn OFF and back ON the main power to recover
Recovered by turning the main power OFF / ON
Check the connection of power supply cooling fan, replace it
Check the connection of power supply cooling fan 2, replace it
Check on connection of the controller fan, Replace the
controller fan
Check on connection of the exhaust fan (front), Replace the
exhaust fan (front)
Check on connection of the exhaust fan (rear), Replace the
exhaust fan (rear)
Check the connection of delivery adhesive fan, replace it
Check the connection of delivery adhesive fan, replace it
Check the connection of secondary transfer exhaust fan, replace
it
Check the connection of fan (front) of process cartridge, replace
it
Check the connection of fan (rear) of process cartridge, replace
it
Replace low-voltage power supply PCB, replace DC controller
PCB
Check the connection of drum unit, replace it
Replace DC driver PCB
Replace DC driver PCB
- Replace the fan shutter motor
- Replace the fan shutter position sensor
- Replace the fan shutter home position sensor
- Replace the DC controller PCB
Chapter 16
16-13

Hide quick links: