Controlling Synchronization In Sub Scanning Direction - Canon Color iR C3480 Service Manual

Table of Contents

Advertisement

[1] Y/M laser driver
[2] BD circuit
[3] C/Bk laser driver
1BD Control Method
Owing to the spatial relationship between the BD circuit and the laser diode, the machine is not capable of detecting the BD signal of each color individually. As
such, it uses the BD signal of Bk to serve as the reference BD signal when generating the BD signal for Y, M, and C.
The following is a timing chart depicting the relationship of the BD signals of individual colors and the video signals:
[1] Reference BD

6.2.1.3 Controlling Synchronization in Sub Scanning Direction

Color iR C3380G / Color iR C2880G / Color iR C3380i / Color iR C3380 / Color iR C2880i / Color iR C2880 / iR C3480 / iR C3480i / iR C3080 / iR C3080i / iR
C2550
The machine executes synchronization in sub scanning direction so as to match the lead edge of an image and the lead edge of paper. This control is executed for
every color, and is controlled by the DC controller.
The following is the sequence of operation:
1) When the print command arrives, the DC controller generates the sub scanning sync signal (PTOP) with reference to its internal timer.
2) The DC controller generates the sub scanning sync signals (Y-TOP, M-TOP, C-TOP, Bk-TOP) of individual colors based on the PTOP signal, and sends them
to the main controller.
3) When these signals arrive, the main controller generates video signals (VDO Y, VDO M, VDO C, VDO Bk) a specific period of time thereafter, and sends
M-CON
D-CON
[3]
[1]
[1]
VDO (C,Bk)
T1
VDO (Y,M)
[2]
F-6-4
VDO
T2
VDO
F-6-5
Chapter 6
0013-8534