Code
Main Cause/Detail of Detection
***: Finisher-Z1 ****: Finisher-Y1, Saddle Finisher-Y2 *****: Puncher Unit
0001 Communication error between the FAX board and the main controller PCB is
detected for the specific number of times.
0004 Access to the modem IC is abnormal.
0008 Access to the port IC is abnormal.
000C Access to the modem IC and port IC is abnormal.
0010 Abnormality is detected when the timer device is open.
0011 Abnormality is detected when the timer device starts.
E677
Abnormality of the external controller
0003 Abnormality of the external controller
Abnormality is detected in configuration check when the external controller
starts up.
0010 Controller for other mode is connected.
0080 Communication with the printer is abnormal after the external controller starts
up properly.
E710
IPC initialization error
0000 Error in initialization of IPC chip
0001 The status fails to be ready within 3 sec after the IPC chip starts up.
E711
IPC communication error
0001 Error is set to the error register of the IPC chip 4 times or more within 1.5 sec. Check on connection of the cable, Replace the ADF controller
E713
Communication error between the finisher and the printer
0000 Communication between the finisher and the copier stops.
E716
Error in communication to cassette pedestal, 2 / 3 delivery unit
0000 Error in data communication with cassette pedestal
0001 Error in data communication with 2 / 3 delivery unit
E717
Communication error with the NE controller
0001 The NE controller connected before the power is turned off fails to be
recognized at power-on.
0002 A break in the IPC, IPC communication fails to recover
E719
Communication error with the coin vender/card reader
0001 The coin vender connected before the power is turned off fails to be recognized
at power-on.
0002 - A break in the IPC cable connected to the coin vender, IPC communication
fails to recover
- A break in the paper pickup/delivery signal line
- Incorrect connection is detected (Short circuit in Tx and Rx of IPC)
0003 In the case of communication error with the coin vender while obtaining the
unit on start-up
0011 The card reader connected before the power is turned off fails to be recognized
at power-on.
0012 A break in the IPC cable connected to the card reader, IPC communication fails
to recover
E730
PDL error
1001 PDL software error
Initialization error when a job starts.
100A PDL software error
System error such as a failure in initialization occurs during job processing.
9004 Open interface communication error
PAI communication error with the external controller
9005 Connection error between the video cable and the external controller is
detected.
A006 PDL communication error
PDL has no response
A007 PDL version mismatch
Machine control software version and PDL control software version do not
match at start-up.
B013 PDL built-in font error
Font data is corrupt at start-up.
C000 Initialization error
C001 HDD access error
16-10
Countermeasures
Check on connection between the FAX board and the main
controller PCB, Replace the FAX board, Replace the main
controller PCB
Replace the main controller PCB
Check on connection of the cable, Re-install the external
controller system
Connect an appropriate controller, Re-install the external
controller system
Check on connection of the cable, Re-install the external
controller system
Check the connection of cable, Replace the DC controller PCB
Check on connection of the cable
PCB, Replace the reader controller PCB
Check on connection of the cable, Replace the finisher
controller PCB, Replace the DC controller PCB
Check cable connection, replace pedestal PCB, replace DC
controller PCB
Check cable connection, replace 2 / 3 delivery unit PCB,
replace DC controller PCB
Check on connection of the cable
To recover from the error: In service mode
COPIER>FUNCTION>CLEAR >ERR
Check on connection of the cable
To recover from the error: In service mode
COPIER>FUNCTION>CLEAR >ERR
Reset PDL, Turn OFF and back ON the main power
Turn OFF and back ON the main power, Check on connection
of the Open interface board/cable, Replace the external
controller, Replace the Open interface board, Replace the main
controller PCB
Reset PDL, Turn OFF and back ON the main power, Check on
connection of the UFR board, Re-install the system, Replace
the main controller PCB, Format and re-install the whole
system.
Reset PDL, Turn OFF and back ON the main power, Format
and re-install the whole system
Turn OFF and back ON the main power, Re-install the system,
Format and re-install the whole system.
Format and re-install the whole system, Replace the main
controller PCB.
Format and re-install the whole system, Replace the HDD,
Replace the main controller PCB.