Installation; Mechanical Installation; General Installation; Slot Selection - Emerson EZMotion User Manual

Table of Contents

Advertisement

3

Installation

This section of the manual will cover basic installation information.
Before installing or removing a Solutions Module in any drive, ensure the AC supply has been disconnected for at
lease 10 minutes and refer to Safety Information on page 1. If using a DC bus supply ensure this is fully discharged
before working on any drive or Solutions Module.
WARNING
3.1

Mechanical Installation

Please refer to the Installation Sheet that comes with the SM-EZMotion module for details on installing the module into the
Unidrive SP/Digitax ST.
3.2

General Installation

The installation of a Solutions Module is illustrated in Figure 3 Fitting a Solutions Module .
Figure 3:
The Solutions Module connector is located on the underside of module (1). Push this into the Solution Module slot (2) located
on the drive until it clicks into place. Note: that some drives require a protective tab to be removed from the Solution Module
slot. For further information, refer to the appropriate drive manual.
3.3

Slot Selection

The SM-EZMotion module may be placed in any of the three available option slots on the Unidrive SP or the two available
option slots on the Digitax ST. The user must indicate which slot the SM-EZMotion module is fitted in using PowerTools Pro
configuration software. The default slot number is Slot 1 in the configuration software.
3.4

Electrical Connections

EZMotion has a single terminal block allowing screw terminal access to the digital I/O.
The terminals are numbered from Terminal 1 on the left to Terminal 7 on the right. The different terminal functions are listed in
the table below.
3.5

Digital I/O Connections

EZMotion is equipped with 4 digital inputs and 2 digital outputs. The I/O are electrically sourcing I/O. All I/O utilize positive logic
meaning that they are active when a positive voltage is applied (15 Vdc to 30 Vdc).
EZMotion User/Programming Guide
Revision A8
2
Fitting a Solutions Module
Terminal #
Function
1
0V Common
2
Input 1
3
Input 2
4
Input 3
5
Input 4
6
Output 1
7
Output 2
www.controltechniques.com
Description
0V Common connection for Digital I/O
Digital Input 1
Digital Input 2
Digital Input 3
Digital Input 4
Digital Output 1
Digital Output 2
1
7

Advertisement

Table of Contents
loading

Table of Contents