the time in which an index should complete its programmed distance. The units for this parameter depend on the current setting of
the TimeBase parameter for the specific index. If TimeBase is set to "Realtime" (default), then the units are Seconds. The user can
program the index time with resolution on 0.001 Seconds (or milliseconds). If TimeBase is set to "Synchronized", the units defined
by the Master Distance Units found on the Master Setup screen.
Index Initiate
Index.#.Initiate
The Index.#.Initiate destination is used to initiate the specific index. The Index is initiated on the rising edge of this function. An Index
cannot be initiated if there is an Home, Jog, or Program in progress, or if the Stop destination or if a travel limit is active. It can be
activated from an assignment or from a program.
Index Limit Distance Hit
Index.#.LimitDistHit
This source is activated when the registration sensor is not found before the Limit Distance is traveled. If the Registration Window is
enabled the sensor must be activated inside the window to be recognized.
Index Name
Index.#.Name
The user can specify an Index name of up to 12 characters.
Enable Index PLS
Index.#.PLSEnable
When Activated, this parameter enables the PLS (programmable limit switch) function for the specified index. It can be controlled
from index view check box or from a program.
Index PLS Off Point
Index.#.PLSOffDist
This an incremental distance from the start of the index to the Index PLS off point. This is an unsigned value and is relative only to
starting position of this index. Index direction does not affect this parameter. Index.#.PLSStatus will be active if the distance traveled
from the start of the index is greater than the Index.#.PLSOnDist and less than the Index.#.PLSOffDist.
Index PLS On Point
Index.#.PLSOnDist
This an incremental distance from the start of the index to the Index PLS On Point. This is an unsigned value and is relative only to
starting position of this index. Index direction does not affect this parameter. Index.#.PLSStatus will be active if the distance traveled
from the start of the index is greater than the Index.#.PLSOnDist and less than the Index.#.PLSOffDist.
Index PLS Status
Index.#.PLSStatus
Controlled by the PLSOn and PLSOff Points, this is relative to the distance commanded since the start of the index.
Index.#.PLSStatus will be active if the distance traveled from the start of the index is greater than the Index.#.PLSOnDist and less
than the Index.#.PLSOffDist.
Index Registration Offset
Index.#.RegistrationOffset
This parameter is the Distance the motor will travel after a valid registration sensor or analog limit value has been detected.
Index Registration Type
Index.#.RegistrationType
This selects either sensor or analog as the registration mark for a registration index.
Index Enable Registration Window
Index.#.RegistrationWindowEnable
This check box enables (if checked) the Registration Sensor valid Window. When active, only registration marks that occur inside
the registration window are seen as valid.
Index Window End
Index.#.RegistrationWindowEnd
This parameter defines the end of the Registration Sensor Valid Window relative to start position of this index. This is an unsigned
202
www.controltechniques.com
EZMotion User/Programming Guide
Revision: A8

Advertisement