Error
Cause
Code
Trip?
(x.50)
128
Y
129
Y
Program Error - Illegal Command
130
Y
131
Y
132
Y
133
Y
134
Y
135
Y
Program Error - Math Divide By
136
Y
137
Y
138
Y
139
Y
Multiplication Operand Too Large
140
Y
Program Error - Math Subtraction
141
Y
142
Y
143
Y
144
Y
145
Y
146
Y
147
Y
148
Y
153
Y
154
Y
155
Y
156
Y
157
Y
EZMotion User/Programming Guide
Revision A8
Error
File Corruption Error - Consult
Factory
File Corruption Error - Consult
Factory
File Corruption Error - Consult
Factory
File Corruption Error - Consult
Factory
File Corruption Error - Consult
Factory
File Corruption Error - Consult
Factory
Program Error - Math Addition
Overflow
Zero
Program Error - Math Divide
Operand Too Large
Program Error - Math
Multiplication Normalization
Failed
Program Error - Math
Program Error - Overflow
Overflow
Program Error - Math Stack
Overflow
File Corruption Error - Consult
Factory
File Corruption Error - Consult
Factory
File Corruption Error - Consult
Factory
File Corruption Error - Consult
Factory
Program Error - Flash Memory
Size Exceeded
Program Error - RAM Memory
Size Exceeded
File Corruption Error - Consult
Factory
File Corruption Error - Consult
Factory
File Corruption Error - Consult
Factory
Program Error - Too Many Wait
For Instructions
File Corruption Error - Consult
Factory
www.controltechniques.com
Possible Reason
User Program has processed an
illegal command
Math addition operation in user
program has resulted in an
overflow of the resultant
parameter
Formula in user program causes
a divide by zero
Normalization of multiplication
parameters in user program has
failed
User Program math process stack
has overflown
User configuration exceeds
available flash memory size
User configuration exceeds
available RAM memory size
No more than nine arguments in
Wait for Instruction
Possible Solution
Re-download original PowerTools
Pro configuration file. If problem
persists, please contact factory.
Verify that the sum of all the
operands in addition formulas will
not result in a value in the
following range:
31
31
-2
< SUM < 2
-1
Make sure that the denominator in
all division formulas is not equal to
zero.
Eliminate any unused Indexes or
Programs and re-download the
PowerTools Pro configuration
Eliminate any unused Indexes or
Programs and re-download the
PowerTools Pro configuration
Limit # of arguments and
redownloads