The X in "SlotX" defines the slot number that the I/O module has been fitted in. For example, if the I/O module is in slot 2, the
parameter would be named Slot2.Input120V.#.In. The # in the previous example is the input number.
All of the I/O points on the SM-I/O 120V module are defined as digital inputs only. The ".In" at the end of the parameter is
optional, so this signal is most often referred to simply as SlotX.Input120V.#.These inputs can be used in a user program, or
on the Assignments view to activate different destination events.
These inputs are updated at the Trajectory Update Rate found on the Setup view in PowerTools Pro.
SM-I/O 120V Module Name
SlotX.Input120V.#.Name
This parameter is only available for SM-I/O120V modules that have been populated in one of the Unidrive SP/Digitax ST slots.
The X in "SlotX" defines the slot number that the SM-I/O120V module has been fitted in. For example, if the I/O Plus module is
in slot 2, the parameter would be named Slot2.Input.#.Name.
Each digital input on the SM-I/O module can be given a name. The name can be used in a user program to reference a
specific input. The name can be up to 12 alphanumeric characters, but must begin with a non-numeric character.
SM-I/O Plus Module IO Direction
SlotX.IO.#.Direction
This parameter is only available for SM-I/O Plus module that has been populated in one of the Unidrive SP/Digitax ST slots.
The X in "SlotX" defines the slot number that the SM-I/O Plus module has been fitted in. For example, if the I/O module is in
slot 2, the parameter would be named Slot2.IO.#.Direction.
The first three digital I/O points on the SM-I/O Plus module (pins 2, 3, and 4) are configured as Inputs or Outputs using
PowerTools Pro software. The SlotX.IO.#.Direction parameter is used to configure whether the I/O point acts as a digital input
or digital output. Valid entries for this parameter are selInput or selOutput. This parameter is modified automatically when the
user changes the settings on the Slot X view.
SM-I/O Plus Module IO Status
SlotX.IO.#.In
This parameter is only available for SM-I/O Plus module that has been populated in one of the Unidrive SP/Digitax ST slots.
The X in "SlotX" defines the slot number that the SM-I/O Plus module has been fitted in. For example, if the I/O Plus module is
in slot 2, the parameter would be named Slot2.IO.#.In.
The first three digital I/O points on the SM-I/O Plus module (pins 2, 3, and 4) are configured as Inputs or Outputs using
PowerTools Pro software. If the I/O point has been configured as a digital input, then the SlotX.IO.#.In signal can be used in a
user program to check the status of inputs, or on the Assignments view to activate different signals.
NOTE
This parameter will appear on the Assignments view under the Inputs group of Sources even if the I/O point has been
configured as a digital output.
SlotX IO Name
SlotX.IO.#.Name
This parameter is only available for SM-I/O Plus module that have been populated in one of the Unidrive SP/Digitax ST slots.
The X in "SlotX" defines the slot number that the SM-I/O Plus module has been fitted in. For example, if an SM-I/O module is
in slot 2, the parameter would be named Slot2.IO.#.Name.
Each digital I/O point on the SM-I/O Plus module can be given a name. The name can be used in a user program to reference
a specific I/O point. The name can be up to 12 alphanumeric characters, but must begin with a non-numeric character.
Slot X IO State
SlotX.IO.#.Out
This parameter is only available for SM-I/O Plus module that have been populated in one of the Unidrive SP/Digitax ST slots.
The X in "SlotX" defines the slot number that the I/O module has been fitted in. For example, if a SM-I/O Plus module is in slot
2, the parameter would be named Slot2.IO.#.Out.
The first three digital I/O points on the SM-I/O Plus module (pins 2, 3, and 4) are configured as Inputs or Outputs using
PowerTools Pro software. If the I/O points have been configured as digital outputs, then the SlotX.IO.#.Out signal can be used
in a user program to activate an output, or on the Assignments view to activate when a specified Source event activates. If
assigned to a source on the Assignments view, when the source event activates, the output that it is assigned to will turn on.
NOTE
This parameter will appear on the Assignments view under the Outputs group of Destinations even if the I/O point has been
configured as a digital input.