Errors View - Emerson EZMotion User Manual

Table of Contents

Advertisement

Parameters
MotionStop
SoftDriveDisable
AbsolutePosnValid
InPosn
Feedhold
FeedRateOverride
FeedRateDeactivate
FoldbackActive
SoftwareTravelLimitMinusActive
SoftwareTravelLimitPlusActive
TorqueLimitActive
Profile.0.MotionStop
Profile.0.FeedHold
Profile.1.MotionStop
Profile.1.FeedHold
Close - The Close button will close the Select Drive Parameters window, while the Watch Window will remain open.
Help - The Help button will give associated help on the Watch Window setup.
User Level - The User Level setting is a filter for the parameters that are seen in the Select Drive Parameters list. If set to
Easy, the parameters used in most basic applications will be seen while the more advanced parameters are hidden. If User
Level is set to Detailed, the parameters used in more advanced applications will be added to the list. If set to Too Much, then
all parameters available in the system will be seen in the list. This allows the user to select the User Level they are most
comfortable with to avoid confusion. If a parameter has been selected and the User Level is changed, then the selected
parameter will remain selected.
Within the Select Parameters window the user can change the value of parameters in the drive's RAM memory. Click on a
parameter in the Parameters Displayed in Watch Window pane. Just below the pane the parameter that was selected will be
shown along with either a check box, text box or list box. The type of box is depended on the parameter selected. Enter the
new parameter value and press the Write button.The data should change in the watch window to the new value.

14.3.2 Errors View

The Errors View in PowerTools Pro helps the user diagnose problems by displaying any active errors or trips. If online when an
error activates, an error pop-up window will appear that shows the active error. There are two buttons on the pop-up window
that allow the user to clear an error and trip or simply ignore it and remove the pop-up window. An example of the pop-up
window is shown in Figure 183.
EZMotion User/Programming Guide
Revision A8
Expected Value to get Motion
False
False
True
True
False
100%
False / True
False
False
False
False
False
False
False
False
www.controltechniques.com
Comments
Motion is stopped on motion stop.
Motion is prevented by SoftDriveDisable.
Absolute indexes can not executed until the Absolute
position is defined.
If using "In Position" the last index is not considered
complete until this status is met. So motion will stop if
you can not achieve in position. While running this is
expected to be false as it is only true at the end of a
move and prior to starting a new move.
Feed Hold stops motion.
Feed rate scales the speed of the Motion. 100%
scaling indicates one to one scaling.
Activate to disable FeedRate. If feedrate is 100% it
does not matter.
When Foldback is active it indicates a current
overload and the Foldback circuit is limiting the
current. Foldback in it's self indicates motor selection
of wiring problems that effect motor motion.
Motion stops when a travel limit is active.
Motion stops when a travel limit is active.
Torque limits may effect motor motion as it reduces
motor generated torque.
Each profile has it's own Stop. To get motion out of
this profile this parameter must be false.
Each profile has it's own Feedhold. To get motion out
of this profile this parameter must be false.
Each profile has it's own Stop. To get motion out of
this profile this parameter must be false.
Each profile has it's own Feedhold. To get motion out
of this profile this parameter must be false.
243

Advertisement

Table of Contents
loading

Table of Contents