Emerson EZMotion User Manual page 244

Table of Contents

Advertisement

Error
Cause
Code
Trip?
(x.50)
158
Y
159
Y
160
Y
161
Y
162
Y
163
Y
164
Y
165
Y
166
Y
171
Y
172
Y
173
Y
174
Y
175
Y
14.2
Analog Outputs
The Unidrive SP has two Analog Outputs that can be configured to represent any base drive parameter (00.00 - 21.51). The default
configuration for the two drive analog outputs are Speed Feedback (3.02) and Active Current (4.02). Using this method will
automatically update the analog output value.
To configure the drive Analog Output to represent an SM-EZMotion module parameter, the Analog Output Source of the drive (7.19
or 7.22) must be set to a drive parameter in Menu 20 (20.21 through 20.40). Menu 20 parameters 21 through 40 must be used
because they are 32-bit parameters. Once the Analog Output Source has been set to a 32-bit parameter, the SM-EZMotion user
program must be coded to write the value of the desired SM-EZMotion parameter to the 32-bit menu parameter. Below is an
example of this process.
240
Error
File Corruption Error - Consult
Factory
File Corruption Error - Consult
Factory
File Corruption Error - Consult
Factory
File Corruption Error - Consult
Factory
File Corruption Error - Consult
Factory
File Corruption Error - Consult
Factory
File Corruption Error - Consult
Factory
File Corruption Error - Consult
Factory
Program Error - EZMotion
Parameter Write Out of Range
Invalid Slot 1 Selection
Invalid Slot 2 Selection
Invalid Slot 3 Selection
File Corruption Error - Consult
Factory
Module Output Overload
www.controltechniques.com
Possible Reason
Value written to SM-EZMotion
parameter in user program is out
of range
Option module selected for Slot 1
in PowerTools Pro file does not
match actual module type fitted
Option module selected for Slot 2
in PowerTools Pro file does not
match actual module type fitted
Option module selected for Slot 3
in PowerTools Pro file does not
match actual module type fitted
EZMotion can only supply 20mA
maximum total output current. If
this fault occurs, the digital output
device attached to the module
outputs is drawing too much
current.
Possible Solution
Switch module located in Slot 1 to
match module type selected in
PowerTools Pro file. Alternatively,
update the PowerTools Pro
configuration to match the module
type actually fitted, and then re-
download the configuration.
Switch module located in Slot 2 to
match module type selected in
PowerTools Pro file. Alternatively,
update the PowerTools Pro
configuration to match the module
type actually fitted, and then re-
download the configuration.
Switch module located in Slot 3 to
match module type selected in
PowerTools Pro file. Alternatively,
update the PowerTools Pro
configuration to match the module
type actually fitted, and then re-
download the configuration.
Modify circuitry of devices
connected to the EZMotion digital
outputs so that they draw no more
than 20mA total.
EZMotion User/Programming Guide