Quick Start Guide
00825-0100-4212, Rev BA
December 2020
Rosemount
BP20E Power Module for
Wireless Corrosion Transmitter

Advertisement

loading

Summary of Contents for Emerson Rosemount ET410

  • Page 1 Quick Start Guide 00825-0100-4212, Rev BA December 2020 ™ Rosemount BP20E Power Module for Wireless Corrosion Transmitter...
  • Page 2 Rosemount Wireless Permasense Corrosion Transmitter. It does not provide instructions for configuration, diagnostics, maintenance, service, troubleshooting or intrinsically safe (I.S.) installations. Refer to the Rosemount Wireless Permasense Corrosion Transmitter Reference Manual for more instruction. The manual and this guide are also available electronically on Emerson.com \Permasense. WARNING Explosion hazard Explosions could result in death or serious injury.
  • Page 3: Table Of Contents

    December 2020 Quick Start Guide Contents Overview............................5 Physical installation........................6 Verify operation........................... 8 Disposal/recycling........................9 Product certifications......................... 10 Quick Start Guide...
  • Page 4 Quick Start Guide December 2020 Emerson.com/Rosemount...
  • Page 5: Overview

    December 2020 Quick Start Guide Overview Warning on product labels The Rosemount BP20E Power Module for Wireless Corrosion Transmitters each have a warning printed on them. In each case the warning text is the same. Below is a figure that shows the label. The text of the warning is: “Use only with approved sensor –...
  • Page 6: Physical Installation

    3. Clip on the power module as shown in Figure 2-1. 4. Fit the two M3 retaining bolts using a 2.5 mm AF hex key. 5. The sensor will resume normal operation. No configuration is required. Figure 2-1: Rosemount BP20E Installation Emerson.com/Rosemount...
  • Page 7 December 2020 Quick Start Guide Power module removal To remove the power module: 1. Remove the two M3 retaining bolts using a 2.5 mm AF hex key. 2. Depress the clip on the front of the power module (on the opposite side to the sensor label).
  • Page 8: Verify Operation

    December 2020 Verify operation Sensor operation Correct sensor operation can be verified by: • Checking the join status in Gateway Manager software, OR • Checking in Data Manager that data has been received once the sensor has joined the gateway. Emerson.com/Rosemount...
  • Page 9: Disposal/Recycling

    December 2020 Quick Start Guide Disposal/recycling Disposing of depleted power modules 1. Dispose in accordance with applicable laws and regulations in your country and state. 2. Disposal should only be performed by authorized professionals in accordance with applicable requirements for hazardous waste transportation and disposal.
  • Page 10: Product Certifications

    A copy of the EU Declaration of Conformity can be found at the end of the Quick Start Guide. The most recent revision of the EU Declaration of Conformity can be found at Emerson.com/Rosemount. Ordinary location certification As standard, the device has been examined and tested to determine that the...
  • Page 11 December 2020 Quick Start Guide Specific Condition for Safe Use (X): The polymer enclosure may present a potential electrostatic ignition hazard and must not be rubbed or cleaned with a dry cloth. International Certificate: IECEx BAS 18.0088X Standards: IEC 60079-0:2017 Edition 7.0, IEC 60079-11: 2011 Edition 6.0 Markings: Ex ia IIC T4 Ga, T = -50 °C to +75 °C, IP67...
  • Page 12 Applicable standards: EN 60079-0:2018, EN60079-11:2012, IEC 60079-0:2017, IEC 60079-11:2011 Markings: Ex ia IIC T4 Specific condition for safe use (X): See certificate. 5.13 Japan I4 CML Intrinsically Safe (IS) Included on sensor certificates: CML 19JPN2097X, CML 19JPN2339X Standards: JNIOSH-TR-46-1:2015 JNIOSH-TR-46-6:2015 Emerson.com/Rosemount...
  • Page 13 December 2020 Quick Start Guide Markings: Ex ia IIC T4 Ga (-50 °C ≤ T ≤ +75 °C) Specific condition for safe use (X): See certificate for specific conditions of safe use. 5.14 Declaration of Conformity Figure 5-1: Declaration of Conformity Quick Start Guide...
  • Page 14 Quick Start Guide December 2020 5.15 China ROHS Emerson.com/Rosemount...
  • Page 15 December 2020 Quick Start Guide Quick Start Guide...
  • Page 16 The Emerson logo is a Twitter.com/Rosemount_News trademark and service mark of Emerson Electric Facebook.com/Rosemount Co. Rosemount is a mark of one of the Emerson Youtube.com/user/ family of companies. All other marks are the RosemountMeasurement property of their respective owners.